Z-Wave Configuration Settings
NO
.
Name
Def.
Valid
Description
1 Basic Set
Level
99
0 ~ 99
Setting the BASIC command value to turn
on the light. The 0x63 means turn on
the light. For dimmer equipment 1 to 99
means the light strength.
0 means turn off the light.
3 PIR
Sensitivity
80
0 ~ 99
PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected long
distance, but if there is more noise signal
in the environment, it will re-trigger too
frequency.
4 Operation
Mode
0x31
All
Operation mode. Using bit to control.
1
Bit0
: Setting the temperature scale. (1:
Fahrenheit, 0:Celsius)
0
Bit1
: Reserve.
0
Bit2
: Reserve.
0
Bit3
: Reserve.
1
Bit4
: Disable the illumination report after
event triggered.
(1:Disable, 0:Enable)
1
Bit5
: Disable the temperature
report after event triggered.
(1:Disable, 0:Enable)
0
Bit6
: Reserve.
NO
.
Name
Def.
Valid
Description
0
Bit7:
Reserve.
5
Customer
Function
3
All
Customer function switch, using bit
control.
1
Bit0
: Tamper On/Off (1:On, 0:Off)
1
Bit1
: Red LED On/Off (1:On, 0:Off)
0
Bit2
: Motion Off.(1:On, 0:Off)
Note: Depends on the Bit2,
1: Report Notification CC,
Type: 0x07, Event: 0xFE
0
Bit3
: Reserve.
0
Bit4
: Reserve.
0
Bit5
: Reserve.
0
Bit6
: Reserve.
0
Bit7:
Reserve.
6
PIR Re-
Detect
Interval
Time
6
1 ~ 60
In the normal mode, after the PIR motion
detected, setting the re-detect time. 10
seconds per tick, default tick is 6 (60
seconds).
Setting the suitable value to prevent
received the trigger signal too frequently.
Also can save the battery energy.
Notice: If this value bigger than the
configuration setting NO. 7 There is a
period after the light turned off and the
PIR not start detecting.
7
Turn Off
Light Time
7
1 ~ 60 After turn on the lighting, setting the
delay time to turn off the lighting when
the PIR motion is not detected. 10
7