background image

Add to/Remove from Z-Wave

TM

 Network

There  are two  tamper keys in the device,  one is in the  back side,

another is in the front side.  Both of them  can add, remove, reset or

association from Z-Wave

TM

 network.

The table below lists an operation summary of basic Z-Wave functions. 

Please refer

to the instructions for your Z-WaveTM Certificated Primary Controller to

access the

Setup function, and to Add/Remove/associate devices

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 2 seconds 

to enter the inclusion mode.

3. After add successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Remove

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 2 seconds 

to enter the exclusion mode.

Node ID has been excluded.

Reset

Notice: Use this procedure only in the event 

that the primary controller is lost or 

otherwise inoperable.

1. Pressing button four times and keep about 5 

seconds.

2. IDs are excluded and all settings will reset to 

factory default.

SmartStart

 

1. Product has a DSK string, you can key in first five 

digit to increment smart start process, or you can 

scan QR code.

2. SmartStart enabled products can be added into a 

Z-Wave network by scanning the Z-Wave QR Code 

present on the product with a controller providing 

SmartStart inclusion. No further action is required 

and the SmartStart product will be added automati-

cally within 10 minutes of being switched on in the 

network vicinity.  

*notice1:The QR code can be found on the device  

or in the box.

Association

3. Have Z-Wave

TM

 Controller entered association 

mode.

4. Pressing tamper key three times within 1.5 seconds

to enter the association mode.

Note: The device support 2 groups. The group 1 is for 

receiving the report message, like triggered event, 

temperature, illumination etc. The group 2 is for light 

control, the device will send the “Basic Set” command 

to this group. A group  one support 1 nodes maximum 

and group  two support 5 nodes maximum.

Failed or success in add/remove the node ID can be viewed 

from Z-Wave

TM

 Controller.

3

Summary of Contents for PST07

Page 1: ...oduct supports Over The Air OTA feature for the products firmware upgrade This product can be included and operated in any Z WaveTM network with other Z WaveTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 serie...

Page 2: ...arking CE NCC Specifications are subject to change and improvement without notice Function Compare A B C D Model Description PST07 A Wall mount PST07 B Ceiling mount with Square shape PST07 C Ceiling mount with Round shape PST07 D Wall mount with lens cover Troubleshooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude t...

Page 3: ...ocedure only in the event that the primary controller is lost or otherwise inoperable 1 Pressing button four times and keep about 5 seconds 2 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment smart start process or you can scan QR code 2 SmartStart enabled products can be added into a Z Wave network by...

Page 4: ...e Security 0x07 Event Tampering Product covering removed 0x03 Temperature Report When the PIR motion detected state changed the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Temperature 0x01 Temperature differential report This function default is enabled to disable this function by setting the configuration NO 12 to 0 In the default when the ...

Page 5: ...function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_C...

Page 6: ...t let the device facing the window or the sunlight 3 Don t let the device facing the source of heat For instance the heater or the air condition Battery Installation When the device reports the low battery message users should replace the battery The battery type is CR123A 3 0V 6 ...

Page 7: ...e the temperature report after event triggered 1 Disable 0 Enable 0 Bit6 Reserve NO Name Def Valid Description 0 Bit7 Reserve 5 Customer Function 3 All Customer function switch using bit control 1 Bit0 Tamper On Off 1 On 0 Off 1 Bit1 Red LED On Off 1 On 0 Off 0 Bit2 Motion Off 1 On 0 Off Note Depends on the Bit2 1 Report Notification CC Type 0x07 Event 0xFE 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Res...

Page 8: ...s 1 minute 12 Temperature Differential Report 2 1 100 The temperature differential to report 0 means turn off this function The unit is 0 5 Fahrenheit Enable this function the device will detect per minutes And when the temperature is over 140 NO Name Def Valid Description degree Fahrenheit it will continue report Enable this functionality will cause some issue please see the detail in the Tempera...

Page 9: ...urchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C http www philio tech com FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea...

Page 10: ...unction with any other antenna or transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging you...

Reviews: