Philio PSE04 Quick Start Manual Download Page 7

otherwise,   the   firmware   will   be   broken,   and   the   device   will   be
nonfunctional. 

Z-Wave Configuration Settings

 

Notice 1:

 All of the configuration, the data size is 1.

Notice 2: 

The reserve bit or not supported bit is allowed any value, but no

effect.

Notice  3:

  The   PSE04   must   stay   awake   for   at   least   2   seconds   after

communicating,   so   therefore   the   more   communication,  the  

power

consumption

 

fast, please pay attention to use  

configuration

  NO.1, NO.4,

NO.5, NO.6.

NO.

Name

Def. Valid 

Description

1 Auto Report 

Tick Interval

0x1E 0~255 The interval time for auto report 

each tick.

2 Sound 

Duration

0x06 0~255 Play sound duration, 1 tick is 30 

seconds.

3 Customer 

Function

0x00

All

Customer function switch, using 

bit control.

0

Bit0

: Disable Trigger Alarm. 

0:Enable , 1:Disable.

0

Bit1

: Disable Sound. Only using 

optical alarm. 0:Enable , 

1:Disable.

0

Bit2

: Temperature Unit. 

0:Fahrenheit , 1:Celsius.

0

Bit3

: Reserve.

0

Bit4

: Reserve.

0

Bit5

: Reserve.

0

Bit6

: Reserve.

0

Bit7

: Reserve.

4

Auto Report 

Temperature 

Time

0x0C 0~255 The interval time for auto report 

the temperature.

5

Temperature 

Differential 

Report

0x00 0~255 The temperature differential to 

report.

6 Auto Report 

Battery Time

0x0C 0~255 The interval time for auto report 

the battery level.

7 Play Sound 

Control

0x43

All

Control play sound's level and 

which sound.

3

Bit0~1

: Play sound's level. 

Level 1~3, 0: Level 3.

0

Bit2

: Reserve.

0

Bit3

: Reserve.

4

Bit4~7

: Which sound id will 

play, when control form 

controller.

Sound ID 1~6, 0: Disable.

Z-Wave Supported Command Class

Command Class

Version

Required Security Class

Z-Wave Plus™ Info

2

None

Security

1

None

7

Summary of Contents for PSE04

Page 1: ...ns All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve ab...

Page 2: ...ect to change and improvement without notice Troubleshooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again Overview 2 ...

Page 3: ...y Installation When the device report the low battery message The user should replace the battery to new one The battery type is AA 1 5V Please loosen the screw on the back cover to release the front cover 3 ...

Page 4: ...ey in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment SmartStart process or you can s...

Page 5: ...des in the group 1 Notification Report V8 Notification Type Siren 0x0E Event Siren active 0x01 Siren idle 0x00 Temperature Report When the temperature differential over the device will unsolicited to send the Sensor Multilevel Report to the nodes in the lifeline group Sensor Type Temperature 0x01 Temperature differential report This function default is disable to enable this function by setting th...

Page 6: ... report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low device will report low battery even every 30 minutes Please change another new ...

Page 7: ...ch using bit control 0 Bit0 Disable Trigger Alarm 0 Enable 1 Disable 0 Bit1 Disable Sound Only using optical alarm 0 Enable 1 Disable 0 Bit2 Temperature Unit 0 Fahrenheit 1 Celsius 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 4 Auto Report Temperature Time 0x0C 0 255 The interval time for auto report the temperature 5 Temperature Differential Report 0x00 0 255 The tem...

Page 8: ...battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 0 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 3 Do NOT place the module device where exists combustible substances or any source of heat fires radiators boiler etc Disposal This...

Page 9: ...ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 This de...

Reviews: