LED Light Indication
The LED light indicates the different modes of the PSE04
State Type
LED Indication
Without Node ID Under normal operation, when the PSE04 has not
been allocated a node ID, the LED light will flash on
and off alternately at 0.5 second intervals. By
pressing the On/Off button, LED light will stop
flashing temporarily.
Learning
Slow flashes once when learning is successful.
Alarm Trigger
All LED flashes until trigger off.
Z-Wave
TM
Message Report
In default the device will using Notification Report to represent the
tamper trigger event.
* Tamper Report:
When the tamper key is pressed over 5 seconds. The device will into
the alarm state. In that state, if the tamper key be released, the device
will unsolicited to send the report to the nodes in the group 1.
Notification Report (V8)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
* Siren State Report:
When the siren start playing or stop the alarm sounds, the device will
unsolicited to send the “Notification Report” to the nodes in the group
1.
Notification Report (V8)
Notification Type: Siren (0x0E)
Event: Siren active (0x01) , Siren idle (0x00)
*Temperature Report:
When the temperature differential over, the device will unsolicited to
send the “Sensor Multilevel Report” to the nodes in the lifeline group.
Sensor Type: Temperature (0x01)
*** Temperature differential report ***
This function default is disable, to enable this function by setting the
configuration NO.5 is greater than 0.
In the default, is disable temperature differential report.
If setting the configuration NO.5 to 1, when the temperature is
changed to plus or minus one degree Fahrenheit (0.56 degree Celsius),
the device will report temperature information to the nodes in the
lifeline group.
The device will measure the temperature in every 10 seconds. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will always report in each measurement.
Notice 1:
The PSE04 must stay awake for at least 2 seconds after
communicating, so therefore the more communication,
the
power
consumption
f
ast, please pay attention to use configuration NO.5.
Notice 2:
This product cannot reflect outdoor temperature immediately
because of the temperature sensor equipped inside rather than surface.