Philio PSE04 Quick Start Manual Download Page 4

Adding to Z-Wave

TM

 Network

There   is   one   tamper   key   on   the   device.   The   tamper   key   can   add,

remove, reset from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, make

sure the primary controller is in the add mode. And then power on the 

device. The device will auto start the SmartStart Inclusion mode. 

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the inclusion mode.

3. After add successful, the LED will light ON 1 second

Remove

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the exclusion mode.

3. Node ID has been excluded.

Reset

Notice: Use this procedure only in the event 

that the primary controller is lost or 

otherwise inoperable.

1. Pressing tamper key four times within 1.5 seconds 

and do not release the tamper key in the 4

th

 

pressed, and the LED will light ON.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the tamper key. If 

successful, the LED will light ON one second. 

Otherwise, the LED will flash once.

3. IDs are excluded and all settings will reset to 

factory default.

SmartStart

1.

Product has a DSK string , you can key in first five 
digit to increment SmartStart process,or you can 
scan QR code.

Ex:mydsk
10209-46687-52248-13629-04783-07465-15776-56519

2.

SmartStart enabled products can be added into a 
Z-Wave network by scanning the Z-Wave QR Code 
present on the product providing SmartStart 
inclusion. No further action is required and the 
SmartStart product will be added automatically 
within 10 minutes of minutes On in the network 
vicinity.
*notice1:The QR code can be found on the device 
PSE04 or on the box.

Association

This machine provides one groups of nodes. Each 

group can set 1 Nodes.

Group 1 is called Lifeline the device will report :

1.Notification report

2.Sensor multilevel report

3.Device Reset Locally Notification

4.Battery Report

5.Indicator Report

Failed or success in including/excluding the node ID can be 

viewed from Z-Wave

TM

 Controller.

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a 

Z-Wave

TM

 network. 

4

Summary of Contents for PSE04

Page 1: ...ns All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve ab...

Page 2: ...ect to change and improvement without notice Troubleshooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again Overview 2 ...

Page 3: ...y Installation When the device report the low battery message The user should replace the battery to new one The battery type is AA 1 5V Please loosen the screw on the back cover to release the front cover 3 ...

Page 4: ...ey in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment SmartStart process or you can s...

Page 5: ...des in the group 1 Notification Report V8 Notification Type Siren 0x0E Event Siren active 0x01 Siren idle 0x00 Temperature Report When the temperature differential over the device will unsolicited to send the Sensor Multilevel Report to the nodes in the lifeline group Sensor Type Temperature 0x01 Temperature differential report This function default is disable to enable this function by setting th...

Page 6: ... report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low device will report low battery even every 30 minutes Please change another new ...

Page 7: ...ch using bit control 0 Bit0 Disable Trigger Alarm 0 Enable 1 Disable 0 Bit1 Disable Sound Only using optical alarm 0 Enable 1 Disable 0 Bit2 Temperature Unit 0 Fahrenheit 1 Celsius 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 4 Auto Report Temperature Time 0x0C 0 255 The interval time for auto report the temperature 5 Temperature Differential Report 0x00 0 255 The tem...

Page 8: ...battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 0 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 3 Do NOT place the module device where exists combustible substances or any source of heat fires radiators boiler etc Disposal This...

Page 9: ...ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 This de...

Reviews: