Philio PSE04 Quick Start Manual Download Page 1

Multiple Sound Siren PSE04

Built-in high accuracy Temperature sensor

The PSE04 is a wireless siren, based on Z-Wave

TM

 technology. It is the

Z-Wave Plus

TM

  product, it support the security, OTA... Those newest

features   of   the  Z-Wave

TM

  technology.  Z-Wave

TM

  is   a   wireless

communication protocol designed for home automation, specifically to

remotely   control   applications   in   residential   and   light   commercial

environments. The technology uses a low-power RF radio embedded or

retrofitted into home electronics devices and systems, such as lighting,

home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  700 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  700   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Specification

Rating

6VDC (AA Battery *4) 

RF distance

Min. 40M indoor,

100M outdoor line of sight,

RF Frequency

868.40 MHz, 869.85 MHz(EU)

908.40 MHz, 916.00 MHz(US)

920.9MHz, 921.7MHz, 923.1MHz

(TW/KR/Thai/SG)

921.40 MHz, 919.80 MHz(ANZ)

869.00 MHz(RU)

865.20 MHz(IN)

916.00 MHz(IL)

RF Maximum Power 

+10dBm (Peak), -10dBm 

(Average)

Dimension

170mm(L) X 48mm (W) X 30(H)

Weight

205g

IP classification

IP44; Outdoor use

Operation temperature

-20 to 55° C

Humidity

85%RH max

FCC ID

RHHPSE04

Marking

CE/NCC

1

Summary of Contents for PSE04

Page 1: ...ns All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve ab...

Page 2: ...ect to change and improvement without notice Troubleshooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again Overview 2 ...

Page 3: ...y Installation When the device report the low battery message The user should replace the battery to new one The battery type is AA 1 5V Please loosen the screw on the back cover to release the front cover 3 ...

Page 4: ...ey in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment SmartStart process or you can s...

Page 5: ...des in the group 1 Notification Report V8 Notification Type Siren 0x0E Event Siren active 0x01 Siren idle 0x00 Temperature Report When the temperature differential over the device will unsolicited to send the Sensor Multilevel Report to the nodes in the lifeline group Sensor Type Temperature 0x01 Temperature differential report This function default is disable to enable this function by setting th...

Page 6: ... report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low device will report low battery even every 30 minutes Please change another new ...

Page 7: ...ch using bit control 0 Bit0 Disable Trigger Alarm 0 Enable 1 Disable 0 Bit1 Disable Sound Only using optical alarm 0 Enable 1 Disable 0 Bit2 Temperature Unit 0 Fahrenheit 1 Celsius 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 4 Auto Report Temperature Time 0x0C 0 255 The interval time for auto report the temperature 5 Temperature Differential Report 0x00 0 255 The tem...

Page 8: ...battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 0 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 3 Do NOT place the module device where exists combustible substances or any source of heat fires radiators boiler etc Disposal This...

Page 9: ...ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 This de...

Reviews: