Philio PAT15 Quick Start Manual Download Page 6

Installation

1. To mount the device on the wall, you can choose using the tape,  or

the screw.

2. Using the screw to fix the flood detector.

Warning: 

1. Before the product is installed, please make sure the surface is clean. 

Especially for the surface of glass and wood, keep it dry before 

installation.

2. It is highly recommended to press the product on double-sided tape 

for 30 seconds. 

Z-Wave Configuration Settings

Notice:

 

* 

All of the configuration, the data size is 1.

All of the configuration after the remove the setting still keep, don't

reset   to   factory   default.   Unless   the   user   execute   the   “RESET”

procedure.

The reserve bit or not supported bit is allowed any value, but no

effect. 

NO.

Name

Def. Valid

Description

1 Auto Report 

Tick Interval

60

1 ~

0xFF

The interval time for auto report 

each tick.(unit:minute)

2 Auto Report 

Battery Time

6

1 ~

0xFF

The interval time for auto report the

battery level.

3 Customer 

Function

13

All

Operation mode. Using bit to 

control.

1

Bit0

: Disable auto report battery 

function.

0 : Disable / 1 : Enable

0

Bit1

: Reserve.

1

Bit2

: Disable auto report flood 

function.

0 : Disable / 1 : Enable

1

Bit3

: Turn off the beep sound.

0 : Disable the beep sound.

1 : Enable the beep sound.

0

Bit4

: Reverse flood signal.

1 : Reverse Mode, Short → Not 

trigger, Open → Trigger.

0 : Normal Mode, Short → Trigger, 

6

Summary of Contents for PAT15

Page 1: ... WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Rated 3VDC CR123A lithium battery Battery life 20 years RF dista...

Page 2: ...ry message The user should replace the battery to new one The battery type is CR123A 3 0V The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top 2 1 2 1 ...

Page 3: ... power on the device just take out the insulation Mylar in the back side of the device The device will auto start the SmartStart Include mode Notice Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode 2 Pressing the tamper...

Page 4: ...eport 4 Indicator Report Group 2 is called Basic set the device will report 1 Basic Set Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake...

Page 5: ... configuration NO 5 Notice The configuration NO 1 could change the tick interval the default value is 60 if setting to 1 that means the minimum auto report interval will be one minute Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will flash three times Please change another new...

Page 6: ... to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Valid Description 1 Auto Report Tick Interval 60 1 0xFF The interval time for auto report each tick unit minute 2 Auto Report Battery Time 6 1 0xFF The interval time for auto report the battery level 3 Customer Function 13 All Operation mode Using bit ...

Page 7: ... Manufacturer Specific 2 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Configuration 4 Highest granted Security Class Notification 8 Highest granted Security Class Battery 1 Highest granted Security Class Disposal This marking indicates that this product should not be di...

Page 8: ...res Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n...