Philio PAT15 Quick Start Manual Download Page 5

And after the flood trigger clear, the device will unsolicited to send the

report to the nodes in the group 1.

Notification Report (V8)
Notification Type: Water Alarm (0x05)

Event: 0x00

* 

Tamper Report: 

The tamper key pressed over 5 seconds. The device will into the alarm

state.   In   that   state,   if   the   tamper   key   be   released,   the   device   will

unsolicited to send the report to the nodes in the group 1.

Notification Report (V8)
Notification Type: Home Security (0x07)

Event: Tampering. Product covering removed (0x03)

* 

Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 1.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Flood state report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 5.

Notice  

: The configuration NO. 1 could change the tick interval, the

default value is 60, if setting to 1, that means the minimum auto report

interval will be one minute. 

Power Up Procedure

* 

Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, the LED will flash

three times. Please change another new battery.

* 

Wake

When the device power on, the device will wake about 20 seconds. In

this duration, the controller can communicate with the device. Normally

the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.

Let the controller into the firmware update mode, and then press the

tamper key once to start the update.

After   finish   the   firmware   download,  

please   don't   remove   the

battery

, otherwise it will cause the firmware broken, and the device

will no function.

After the LED stop flash, it is recommended that the user power up the

device.  

Caution

:   After   remove   the   battery,   please   wait   about   30

seconds, and then re-install the battery.

5

Summary of Contents for PAT15

Page 1: ... WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Rated 3VDC CR123A lithium battery Battery life 20 years RF dista...

Page 2: ...ry message The user should replace the battery to new one The battery type is CR123A 3 0V The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top 2 1 2 1 ...

Page 3: ... power on the device just take out the insulation Mylar in the back side of the device The device will auto start the SmartStart Include mode Notice Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode 2 Pressing the tamper...

Page 4: ...eport 4 Indicator Report Group 2 is called Basic set the device will report 1 Basic Set Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake...

Page 5: ... configuration NO 5 Notice The configuration NO 1 could change the tick interval the default value is 60 if setting to 1 that means the minimum auto report interval will be one minute Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will flash three times Please change another new...

Page 6: ... to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Valid Description 1 Auto Report Tick Interval 60 1 0xFF The interval time for auto report each tick unit minute 2 Auto Report Battery Time 6 1 0xFF The interval time for auto report the battery level 3 Customer Function 13 All Operation mode Using bit ...

Page 7: ... Manufacturer Specific 2 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Configuration 4 Highest granted Security Class Notification 8 Highest granted Security Class Battery 1 Highest granted Security Class Disposal This marking indicates that this product should not be di...

Page 8: ...res Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n...

Reviews: