Flood Water Sensor PAT15                          

The flood sensor PAT15 has flood, based on Z-Wave

TM

 technology.

It is the  Z-Wave

TM

  plus product, it support the security, OTA... Those

newest features of the  Z-Wave

TM

  technology.  Z-Wave

TM

  is a wireless

communication protocol designed for home automation, specifically to

remotely   control   applications   in   residential   and   light   commercial

environments. The technology uses a low-power RF radio embedded or

retrofitted into home electronics devices and systems, such as lighting,

home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  700 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  700   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Specification

Rated

3VDC (CR123A lithium battery)

Battery life

20 years

RF distance

Min. 40M indoor,

100M outdoor line of sight,

RF Frequency

868.40 MHz, 869.85 MHz(EU)

908.40 MHz, 916.00 MHz(US)

920.9MHz, 921.7MHz, 923.1MHz 

(TW/KR/Thai/SG)

RF Maximum Power 

+10dBm (Peak), -10dBm (Average) 

Dimension 

85(L)x28(W)x23(H)mm

Location 

indoor use only

Operation temperature -20

o

C to 50

o

C

Humidity

85%RH max

FCC ID

RHHPAT15

Specifications are subject to change and improvement without notice. 

Indication of battery life :  Flood Alarm Report:1 times/month, Auto
Report: 4 times/ Day, Auto Wake up 1 time/ Day.

Troubleshooting

           

Symptom

Cause of Failure

Recommendation

The device can not 

join to Z-Wave™ 

network

The device may in a Z-

Wave™ network.

Exclude the device 

then include again.

1

Summary of Contents for PAT15

Page 1: ... WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Rated 3VDC CR123A lithium battery Battery life 20 years RF dista...

Page 2: ...ry message The user should replace the battery to new one The battery type is CR123A 3 0V The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top 2 1 2 1 ...

Page 3: ... power on the device just take out the insulation Mylar in the back side of the device The device will auto start the SmartStart Include mode Notice Including a node ID allocated by Z WaveTM Controller means Add or Inclusion Excluding a node ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode 2 Pressing the tamper...

Page 4: ...eport 4 Indicator Report Group 2 is called Basic set the device will report 1 Basic Set Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake...

Page 5: ... configuration NO 5 Notice The configuration NO 1 could change the tick interval the default value is 60 if setting to 1 that means the minimum auto report interval will be one minute Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will flash three times Please change another new...

Page 6: ... to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect NO Name Def Valid Description 1 Auto Report Tick Interval 60 1 0xFF The interval time for auto report each tick unit minute 2 Auto Report Battery Time 6 1 0xFF The interval time for auto report the battery level 3 Customer Function 13 All Operation mode Using bit ...

Page 7: ... Manufacturer Specific 2 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Configuration 4 Highest granted Security Class Notification 8 Highest granted Security Class Battery 1 Highest granted Security Class Disposal This marking indicates that this product should not be di...

Page 8: ...res Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may n...

Reviews: