Philio PAT05 Manual Download Page 4

NO

.

Name

Def.

Valid

Description

3

eCO2 Threshold
line 1

0

1 ~ 100

eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

4

eCO2 Threshold
line 2

0

1 ~ 100

eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

5

eCO2 Threshold
line 3

0

1 ~ 100

eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

6

eCO2 Threshold
line 4

0

1 ~ 100

eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

7

eCO2 Threshold
line 5

0

1 ~ 100

eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

8

TVOC 
Threshold line 1

0

1 ~ 100

TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

9

TVOC 
Threshold line 2

0

1 ~ 100

TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.

NO

.

Name

Def.

Valid

Description

When there is a set value, it means that it 
will exceed or fall below the report.

10

TVOC 
Threshold line 3

0

1 ~ 100

TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

11

TVOC 
Threshold line 4

0

1 ~ 100

TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

12

TVOC 
Threshold line 5

0

1 ~ 100

TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it 
will exceed or fall below the report.

13 
(*)

Customer 
Function

1

0 ~ 127

Customer function switch, using bit 
control.
Caution: The value is unsigned byte, the 
range is from 0x00 ~ 0x7F.

1

Bit0

: Tamper On/Off (1:On, 0:Off)

0

Bit1

: Reserve.

0

Bit2

:  Reserve.

0

Bit3

:  Reserve.

0

Bit4

:  Reserve.

0

Bit5

: Reserve.

0

Bit6

: Reserve.

0

Bit7: 

 Reserve.

4

Summary of Contents for PAT05

Page 1: ...eTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Notice Once you hav...

Page 2: ...05 to send its NIF Note The device support 1 groups The group 1 is for receiving the report message A group one support 1 node maximum Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Z WaveTM Message Report eCO2 Report When ...

Page 3: ...port the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_...

Page 4: ...difference return The Unit is 100ppb 0 means turn off TVOC detected function When there is a set value it means that it will exceed or fall below the report 9 TVOC Threshold line 2 0 1 100 TVOC difference return The Unit is 100ppb 0 means turn off TVOC detected function NO Name Def Valid Description When there is a set value it means that it will exceed or fall below the report 10 TVOC Threshold l...

Page 5: ...his function the device will detect every percentage And when the lightSensor is over 10 percentage it will continue report Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Version 3 Highest granted Security Class Manufacturer Specific 2 Highest granted Security Class Security 2 1 None Device Reset Locally 1 Highest granted Security Class Associa...

Page 6: ...ronment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Ta...

Page 7: ...ice may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other an...