NO
.
Name
Def.
Valid
Description
3
eCO2 Threshold
line 1
0
1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it
will exceed or fall below the report.
4
eCO2 Threshold
line 2
0
1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it
will exceed or fall below the report.
5
eCO2 Threshold
line 3
0
1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it
will exceed or fall below the report.
6
eCO2 Threshold
line 4
0
1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it
will exceed or fall below the report.
7
eCO2 Threshold
line 5
0
1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
When there is a set value, it means that it
will exceed or fall below the report.
8
TVOC
Threshold line 1
0
1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it
will exceed or fall below the report.
9
TVOC
Threshold line 2
0
1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
NO
.
Name
Def.
Valid
Description
When there is a set value, it means that it
will exceed or fall below the report.
10
TVOC
Threshold line 3
0
1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it
will exceed or fall below the report.
11
TVOC
Threshold line 4
0
1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it
will exceed or fall below the report.
12
TVOC
Threshold line 5
0
1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
When there is a set value, it means that it
will exceed or fall below the report.
13
(*)
Customer
Function
1
0 ~ 127
Customer function switch, using bit
control.
Caution: The value is unsigned byte, the
range is from 0x00 ~ 0x7F.
1
Bit0
: Tamper On/Off (1:On, 0:Off)
0
Bit1
: Reserve.
0
Bit2
: Reserve.
0
Bit3
: Reserve.
0
Bit4
: Reserve.
0
Bit5
: Reserve.
0
Bit6
: Reserve.
0
Bit7:
Reserve.
4