Event: Tampering. Product covering removed (0x03)
* Timing Report:
Beside the event triggered could report message, the device also support the timing
unsolicited report of the status.
•
eCO2 report: Every 60 minute report once in default.
It could be changed by setting the configuration NO. 14.
•
TVOC report: Every 60 minute report once in default.
It could be changed by setting the configuration NO. 15.
Notice
: The configuration NO. 14 and 15 could be setting to zero to disable the auto
report. And the configuration NO. 16 could change the tick interval, the default value is
60, if setting to 1, that means the minimum auto report interval will be one minute.
Security Network
The device support the security function. When the device included with a security
controller, the device will auto switch to the security mode. In the security mode, the
follow commands need using Security CC wrapped to communicate, otherwise it will
not response.
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_SENSOR_MULTILEVEL_V11
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting still keep,
don't reset to factory default. Unless the user execute the “RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect.