Philio PAT05 Manual Download Page 1

Air Quality Multi Sensor PAT05                   

The PAT05 multi-sensor is a device that allows you to check the air quality in your
home. The PAT05 Multi-sensor is easy to use and very convenient for your home. Just
set the sensor on the wall of the rooms you would like to control, and you are ready to
go. Moreover, the PAT05 can be integrated to other Z-Wave certified devices, and
controlled with Philio app “Home Mate 2.” You can now protect your family and make
sure there are no gas leaks that can harm those you love the most. Set up your
PAT05 to send regular notifications and take control even when not at home.

This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-
Wave   Plus   messages   to   communicate   to   other   security   enabled   Z-Wave   Plus
products. Z-Wave

TM

 enabled devices displaying the Z-Wave

TM

 logo can also be used

with   it   regardless   of   the   manufacturer,   and   ours   can   also   be   used   in   other
manufacturer’s Z-Wave

TM

 enabled networks.

The product supports Over The Air(OTA) feature for the products firmware upgrade.

This product can be included and operated in any Z-Wave

TM

  network   with other Z-

Wave

TM

 certified devices from other manufacturers and/or  other applications.  All non-

battery operated nodes within the network will act as repeaters regardless of vendor
to increase reliability of the network.

The device adopt the Z-Wave

TM

 500 series chip, when your Z-Wave

TM

 network system

is   all   made   by   Z-Wave

TM

  500   series   devices.   The   network   system   will   have   the

advantages as below.

Notice:

Once you have completed the setup process, Please allow for a 7-Day settling period
for the sensors to adjust to their new environment and to observe a typical cycle of air
quality, based on your activity within a 1 week period.

Add to/Remove from Z-Wave

TM

 Network

There are one tamper keys in the device, in the back side. Can be add, remove, reset
or association from Z-WaveTM network.

The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to Add/Remove/associate devices

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means “

Add

” or 

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  Controller means 

Remove

” or “

Exclusion

”.

Function

Description

Add 
(Inclusion)

1.

Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 2 seconds to enter the

inclusion mode.

1

Summary of Contents for PAT05

Page 1: ...eTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Notice Once you hav...

Page 2: ...05 to send its NIF Note The device support 1 groups The group 1 is for receiving the report message A group one support 1 node maximum Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Z WaveTM Message Report eCO2 Report When ...

Page 3: ...port the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_...

Page 4: ...difference return The Unit is 100ppb 0 means turn off TVOC detected function When there is a set value it means that it will exceed or fall below the report 9 TVOC Threshold line 2 0 1 100 TVOC difference return The Unit is 100ppb 0 means turn off TVOC detected function NO Name Def Valid Description When there is a set value it means that it will exceed or fall below the report 10 TVOC Threshold l...

Page 5: ...his function the device will detect every percentage And when the lightSensor is over 10 percentage it will continue report Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Version 3 Highest granted Security Class Manufacturer Specific 2 Highest granted Security Class Security 2 1 None Device Reset Locally 1 Highest granted Security Class Associa...

Page 6: ...ronment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Ta...

Page 7: ...ice may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other an...

Reviews: