Setting

Description

8

Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)

16

Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.

32

Disable Multi CC in auto report. (1:Disable, 0:Enable)

64

Disable to report battery state when the device triggered. (1:Disable, 0:Enable)

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. 
Size: 1 Byte, Default Value: 18

Setting

Description

0 - 127

The interval time for auto report the battery level.

Parameter 13: Auto Report Temperature Time

The interval time for auto report the temperature. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. 
Size: 1 Byte, Default Value: 18

Setting

Description

0 - 127

The interval time for auto report the temperature.

Parameter 14: Auto Report Humidity Time

The interval time for auto report the humidity. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. 
Size: 1 Byte, Default Value: 18

Setting

Description

0 - 127

The interval time for auto report the humidity.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.Units of one minute.Caution1: Setting
to 0 means turn off all auto report function.Caution2: The value is unsigned byte 
Size: 1 Byte, Default Value: 30

Setting

Description

0 - 255

The interval time for auto report each tick.

Parameter 21: Temperature Differential Report

The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every 10 seconds. And when
the temperature is over 140 degree Fahrenheit, it will continue report. 
Size: 1 Byte, Default Value: 1

Setting

Description

0 - 127

The temperature differential to report. 0 means turn off this function.

Parameter 23: Humidity Differential Report

The humidity differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every 10 seconds. 
Size: 1 Byte, Default Value: 5

Setting

Description

0 - 60

The humidity differential to report.

Technical Data

Summary of Contents for PAT02-B

Page 1: ...th are suited for the same frequency range If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security Otherwise it will automatically turn into a lower level of security to maintain backward compatibility For more information about Z Wave technology devices white papers etc please refer to www z wav...

Page 2: ...ash once 3 IDs are excluded and all settings will reset to factory default Safety Warning for Batteries The product contains batteries Please remove the batteries when the device is not used Do not mix batteries of different charging level or different brands Installation Battery Installation When the device report the low battery message The user should replace the battery to new one The battery ...

Page 3: ... to any Z Wave network The device needs to be added to an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also be removed from a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and E...

Page 4: ... device support the Z Wave firmware update via OTA Let the controller into the firmware update mode and then press the tamper key once to start the update After finish the firmware download the LED will start flash in every 0 5 second At that time please don t remove the battery otherwise it will cause the firmware broken and the device will no function After the LED stop flash it is recommended that the...

Page 5: ...o report the humidity 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 Size 1 Byte Default Value 18 Setting Description 0 127 The interval time for auto report the humidity Parameter 20 Auto Report Tick Interval The interval time for auto report each tick Setting this configuration will effect configuration No 10 No 13 No 14 and No 15 Units of ...

Page 6: ...curity Version Wake Up Zwaveplus Info Controlled Command Classes Wake Up Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary ...

Page 7: ...sku PHIEPAT02 B 7 7 c 2019 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwave eu The template is maintained by Z Wave Europe GmbH The product content is maintained by Z Wave Europe GmbH Supportteam support zwave eu Last update of the product data 2017 12 08 08 14 42 ...

Reviews: