2.   There is only one group for the

switch

Including a node ID allocated by Z-Wave Controller means inclusion.  Excluding a

node

ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-

Wave Controller. 

LED Indication

To distinguish what mode the switch is in, view from the LED for identification. The color of

LED could be blue

cyan

green

orange

pink or red, it represents the power consumption from

light to heavy.

State Type

LED Indication

Normal

Under normal operation, toggle On/Off button between On and Off. When

pressing On, LED lights up, whereas Off, LED is off.

No node ID

Under normal operation, when the Switch has not been allocated a node ID,

the LED flashes on and off alternately at 2-second intervals. By pressing

On/Off button, it will stop flashing temporarily. 

Learning

When PAN38 is in learning mode, LED flashes on and off alternately and

repeatedly at 0.5 second intervals.

Overload

When overload state occurs, the Switch is disabled of which LED flashes on

and off alternately at 0.2 second intervals. Overload state can be cleared by

unplugging and reconnecting the Switch to the wall outlet.

Choosing a Suitable Location

1. Do not locate the Switch facing direct sunlight, humid or dusty place.

2. The suitable ambient temperature for the Switch is 0°C~40°C.

3. Do not locate the Switch where exists combustible substances or any source

of heat, e.g. fires, radiators, boiler etc.

4. After putting it into use, the body of Switch will become a little bit hot of

which phenomenon is normal.

Installation

1. Plug this On/Off Switch into a wall outlet near the load to be controlled.

2. Plug the load into the Switch. Make sure the load to be controlled cannot

 

exceed 13A.

3. Press the button or switch on the load to the ON position.

4. To manually turn ON the Switch, press and release the On/Off button. The

LED will turn ON, and the load plugged into the Switch will also turn ON.

5. To manually turn OFF the Switch, simply press and release the On/Off but-

ton. The LED will turn OFF and the load plugged into the Switch will also

turn OFF.

Programming

1.  Basic Command Class / Binary Switch Command Class

The Switch will respond to BASIC and BINARY commands that are part of

the Z-Wave system.

1-1 BASIC_GET / BINARY_SWITCH_GET

        Upon   receipt   of   the   following   commands   from   a   Z-Wave   Controller,   the

Switch will report its On/Off state to the node asked.

Basic Get Command: 

[Command Class Basic, Basic Get]

Basic Report Command:

Report OFF: 

[Command Class Basic, Basic Report, Value = 0(0x00)]

Report ON:

[Command Class Basic, Basic Report, Value = 255(0xFF)]

Binary Switch Get Command:

[Command Class Switch Binary, Switch

Binary Get]

Summary of Contents for PAN38

Page 1: ...to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load PAN38 1 PAN38 2 PAN38 3 Maximum Load Ampere 10A Resistive load PAN38 4 Switzerland Socket Type Germany type PAN38 1 France type PAN38 2 UK type PAN38 3 Switzerland type PAN38 4 Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 ...

Page 2: ... putting it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Warnung 1 Trennen Sie das Gerät von der Stromzuführung Verwenden Sie das Gerät nicht mit einem DIP Schalter 2 Achten Sie darauf dass die maximale Spannung niemals überschritten wird Warnung für zwisc...

Page 3: ...ion Annotation No node ID The Z Wave Controller does not al locate a node ID to the Switch LED 2 second on 2 second off Add 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Remove 1 Put your Z Wave controller into exclusion mode by following the inst...

Page 4: ...facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Plug this On Off Switch into a wall outlet near the load ...

Page 5: ...Auto report to Grouping 1 Maximum Node 5 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of ...

Page 6: ... Meter Value 4 0xA3 KWh Accumulated power consumption KWh Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KWh 2 2 3 Clearing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will re...

Page 7: ...0 99 3 Z Wave s Configuration Configuration Parameter Function Size Byte Value Unit Default Description 1 Watt Meter 2 0x0000 5s 720 0 Disable Watt Report Period 0x7FFF Report 1 32767 5s 45h 2 KWH Meter Report Period 2 0x0000 0x7FFF 10min 6 0 Disable KWh Report 1 32767 10min 227days 3 Threshold of current for Load caution 2 10 1300 0 01A 1300 1300 0 01A 13A 4 Threshold of KWh for Load caution 2 1 ...

Page 8: ...etting is LAST SWITCH STATE 3 6 Mode of switch off function When the mode of switch On Off is set to 0 any command of switch off will be disabled and the On Off function of include button will be disabled The default setting is enable mode When manual On Off function is disabled the RF com mand can only switch On but not Off This is useful function for keeping the de vice in switch on state 3 7 LE...

Page 9: ...anted Security Class Meter 5 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Notification 8 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Socket Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows Germany ty...

Page 10: ... used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular in stallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one ...