3-8 Auto off timer

 

  Whenever PAN11 switches to on, the auto off timer begin to count down. After the 

timer decrease to zero, it will switch to off automatically. However if Auto off timer 
is set as 0, the auto off function will be disabled. The default setting is 0. 

3-9 RF off command mode : 

        Whenever a switch off command, BASIC_SET

BINARY_SWITCH_SET

SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.   

3-9-1 Switch Off

It switches to OFF state. The default setting is Switch Off. 

3-9-2 Ignore

The switch off command will be ignored. 

3-9-3 Switch Toggle

It switches to the inverse of current state. 

3-9-4 Switch On

It switches to ON state. 

3-10 Manual Switch Report mode : 
      Whenever PAN11 is manually switch on or off, it will send BINARY_SWITCH_ 

REPORT to the node of group1. The default setting is Enable the function. 

 

4.  Protection Command Classes

 

PAN11 supports Protection Command Class version 2, it can protect the switch 

against unintentionally control by e.g. a child. And it can also protect the switch from 

being turned off by setting it

 

in “No RF Control” state. 

 

After being set to 

“Protection by sequence” state, any intentional pressing of On/Off 

button should be hold longer than 1 second, or the switch state will not change. 

However, the operation of learn function does not change, because learning will not 

be protected.   

 

 

5.  Firmware update over the air (OTA)

 

PAN11 is based on 500 series SoC and supports Firmware Update Command Class, 
it  can  receives  the  updated  firmware  image  sent  by  controller  via  the  Z-wave  RF 
media. It is a helpful and convenient way to improve some function if needed. 
 

6.  Command Classes

 

 
The Switch supports Command Classes including… 
* COMMAND_CLASS_ZWAVEPLUS_INFO 
* COMMAND_CLASS_VERSION 
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
* COMMAND_CLASS_SECURITY 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY 
* COMMAND_CLASS_ASSOCIATION_V2 
* COMMAND_CLASS_ASSOCIATION_GRP_INFO 
* COMMAND_CLASS_POWERLEVEL 
* COMMAND_CLASS_SWITCH_BINARY 
* COMMAND_CLASS_BASIC 
* COMMAND_CLASS_SWITCH_ALL 
* COMMAND_CLASS_METER_V3 
* COMMAND_CLASS_CONFIGURATION   
* COMMAND_CLASS_ALARM 
* COMMAND_CLASS_PROTECTION 
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

 

 
 

Socket Type

 

Since the socket type for each country in Europe varies, refer to the outline for each 
socket suited for each country as follows:

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

Germany type PAN11-1B

 

   

France type PAN11-2B

 

Summary of Contents for PAN11

Page 1: ...ernately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet Note Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seco...

Page 2: ... locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Plug this On Off Switch into a wall ou...

Page 3: ... Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W 2 1 3 Overload alarm report When PAN11 detects the current is more than...

Page 4: ...ll report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 Size 2 Meter Value V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load cu...

Page 5: ...ery 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold value if the setting value is 1300 when the load current of Relay1 over this value PAN11 will send current meter report to warn the Group1 node the R...

Page 6: ...ed off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN11 is based on 500 series SoC and supports Firmware Update Co...

Page 7: ...eep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 14 5A Resistive load Specification Operating Voltage 100 240VAC 50Hz 60Hz Maximum Load 13A Resistive load Range Minimum 40m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU CN PAN11 1B 2B 3B 8B 908 40MHz 916 00MHz UL 922 927MHz TW JP PAN11...

Page 8: ...r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer ...

Reviews: