Meter Report Command:

 

[Command  Class  Meter

Meter  Report

Rate  Type  =  0x01

Meter  Type  = 

0x01

  Precision = 2

Scale = 0x06

Size = 1 Bytes

Meter Value(PF)]

 

 
Example: 
Scale = 0x06 (PF) 
Precision = 2 
Size = 1 (1 Byte of    PF) 
Meter Value 1 =    0x63(PF)    (It means that the load power factor is 0.99) 
 

3.    Z-

Wave’s Configuration

 

 

Configuration 

Parameter

 

Function

 

Size 

(Byte)

 

Value

 

Unit

 

Default

 

Description

 

1

 

Watt Meter 

Report Period

 

2

 

0x01- 

0x7FFF

 

5s

 

720

 

720*5s=3600s=1 hour

 

2

 

KWH Meter 

Report Period

 

2

 

0x01- 

0x7FFF

 

10min

 

6

 

6*10min=1 hour

 

3

 

Threshold of 
current for Load 
caution

 

2

 

10-1300

 

0.01A

 

1300

 

1300*0.01A = 13A

 

4

 

Threshold of 
KWh for Load 
caution

 

2

 

1-10000

 

1KWh

 

10000

 

 

5

 

Restore switch 
state mode

 

1

 

0-2

 

 

 

1

 

0 : Switch off 

1 : Last switch state 

2 : Switch on

 

6

 

Mode of Switch 
Off function

 

1

 

0-1

 

 

1

 

0 : Disable 

1 : Enable

 

7

 

LED indication 
mode

 

1

 

1-3

 

 

1

 

1 : Show switch state 

2 : Show night mode 

3 : One flash mode

 

8

 

Auto off timer

 

2

 

0-0x7FFF

 

1s

 

0

 

0 : Disable auto off 

function 

1-0x7FFF : 1s ~ 

32767s

 

9

 

RF off 
command mode

 

1

 

0-3

 

 

0

 

0 : Switch off 

1 : Ignore 

2 : Switch toggle 

3 : Switch on

 

11

 

Manual Switch 
Report mode

 

1

 

0-1

 

 

1

 

0 : Disable 

1 : Enable

 

 
 

3-1

 Watt 

Meter Report Period: 

    If  the  setting  is  configured  for  1hour  (set  value  =720),  the  PAN11  will  report  its 

instant power consumption every 1 hour to Group1 node.    The maximum interval 
to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 

 

3-2 KWH Meter Report Period: 

      If  the  setting  is  configured  for  1hour  (set  value  =6),  the  PAN11  will  report  its 

Accumulated  Power  Consumption  (KW/h)  every  1  hour  to  Group1  node.    The 
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 
days (10min*32767/1440=227.55 days). 

 

3-3 Threshold of current for Load Caution 

This is a warning when the current of load over the preset threshold value, if the 
setting value is 1300, when the load current of Relay1 over this value, PAN11 
will send current meter report to warn the Group1 node, the Range of the setting 
value is from 10 to 1300,and the default value is 1300. 

3-4 Threshold of KWh for Load Caution 

This is a warning when the KWh of load over the preset threshold value, If the 
setting value is 10000, when the Accumulated Power Consumption of Relay1 over   
this value, PAN11 will send KWH meter report to warn the Group1 node, 
minimum value is 1KWh and default value is 10000 kWh. 

3-5 Restore switch state mode : 

  Whenever the AC power return from lost, PAN11 will restore the switch state which 

could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The default setting 

is LAST SWITCH STATE. 

3-6 Mode of switch off function : 

  When  the  mode  of  switch  On/Off  is  set  to  0,  any  command  of  switch  off  will  be 

disabled  and  the  On/Off  function  of  include  button  will  be  disabled.  The  default 
setting  is  enable  mode.  When  manual  On/Off  function  is  disabled,  the  RF 
command can only switch On but not Off. This is useful function for keeping the 
device in switch on state. 

3-7 LED indication mode : 

  3-7-1 Show Switch State

When switch is on, LED is on. When switch is off, LED is 

off. The default setting is Show Switch State. 

  3-7-2 Show Night mode

When switch is on, LED is off. When switch is off, LED is 

on. 

  3-7-3 One Flash mode

When the state of switch changes, LED will be on only one 

Summary of Contents for PAN11

Page 1: ...ernately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet Note Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seco...

Page 2: ... locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Plug this On Off Switch into a wall ou...

Page 3: ... Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W 2 1 3 Overload alarm report When PAN11 detects the current is more than...

Page 4: ...ll report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 Size 2 Meter Value V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load cu...

Page 5: ...ery 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold value if the setting value is 1300 when the load current of Relay1 over this value PAN11 will send current meter report to warn the Group1 node the R...

Page 6: ...ed off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN11 is based on 500 series SoC and supports Firmware Update Co...

Page 7: ...eep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 14 5A Resistive load Specification Operating Voltage 100 240VAC 50Hz 60Hz Maximum Load 13A Resistive load Range Minimum 40m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU CN PAN11 1B 2B 3B 8B 908 40MHz 916 00MHz UL 922 927MHz TW JP PAN11...

Page 8: ...r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer ...

Reviews: