3-3 Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the

setting   value   is  1100,   when   the   load   current   of   Relay1   over   this   value,

PAN03/PAN10 will send current meter report to warn the Group1 node, the Range

of the setting value is from 10 to 1100, and the default value is 1100.

3-4 Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value,  if the

setting  value  is  10000,   when  the Accumulated  Power Consumption  of  Relay1

over  this value, PAN03/PAN10  will send KWH meter report to warn the Group1

node, minimum value is 1KWh and default value is 10000 kWh.

3-5 Restore switch state mode:

  Whenever the AC power return from lost, PAN03/PAN10  will restore the switch

state which could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The

default setting is LAST SWITCH STATE.

3-6 Manual On/Off Mode:

The On/Off function of S1

S2 and learn switch can be disabled or enabled by this

parameter, default value is Enable. But the learning operation won’t be affected.  

When manual On/Off function is disabled, the RF command can only switch On 

but not Off. This is useful function for keeping the device in switch on state.

3-7 LED indication mode:

 3-7-1 Show Switch State

When switch is on, LED is on. When switch is off, LED

is off. The default setting is Show Switch State.

 3-7-2 Show Night mode

When switch is on, LED is off. When switch is off, LED

is on.

 3-7-3 One Flash mode

When the state of switch changes, LED will be on only

one second, then LED keeps off.

3-8 Auto off timer

 Whenever PAN03/PAN10 switches to on, the auto off timer begin to count down.

After the timer decrease to zero, it will switch to off automatically. However if Auto

off timer is set as 0, the auto off function will be disabled. The default setting is 0.

3-9 RF off command mode

 Whenever a switch off command, BASIC_SET

BINARY_SWITCH_SET

SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 

3-9-1 Switch Off

It switches to OFF state. The default setting is Switch Off.

3-9-2 Ignore

The switch off command will be ignored.

3-9-3 Switch Toggle

It switches to the inverse of current state.

3-9-4 Switch On

It switches to ON state.

3-10 Edge mode

Pulse mode and Edge-Toggle mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle

mode, default value is Edge mode. But this parameter is useless to PAN10.

3-10-1 Edge mode: this mode is suitable for the bi-stable wall switch that has indica-

tor point on the switch, and the same position correspond to same state of re-

lay1. If the PAN03/PAN10 relay change the state because of receiving Z-

Wave RF command, it may need two times of change (switch on to off or 

switch off to on) to let relay back to the correspond state. Manual switch S2 is

disabled in this mode.

3-10-2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the 

state of Relay1.

3-10-3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, 

whenever change the state of the wall switch will also swap the state of Re-

lay1.

3-11 Manual Switch Report mode :

9

Summary of Contents for PAN03

Page 1: ...PAN03 PAN10 Switch Module with meter Fig 1 PAN03 Assembling 1 ...

Page 2: ...the switch will reset its overload condition to normal status Adding to Z WaveTM Network In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a n...

Page 3: ...tening Z Wave device so associations may be added or removed by a controller at any time Or If your controller requires to have the PAN03 send a node information frame or NIF for associations then pressing the On Off button three times within 2 seconds will cause the PAN03 to send its NIF 2 There are only one group for the switch Adding a node ID allocated by Z Wave Controller means inclusion Remo...

Page 4: ...humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Put the in wall switch into a wall box and connect the AC power wire L N to PAN0...

Page 5: ... on Command Class Switch Binary Switch Binary Set Value 0 0x00 the load attached to the Switch turns off 1 Z Wave s Groups Association Command Class Version 2 The Switch can be set to send reports to associated Z Wave devices It supports one association group with one node support for Grouping 1 For group 1 the Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BI...

Page 6: ... Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 2 2 2 Accumulated Power Consumption K...

Page 7: ... load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 2 Bytes of ...

Page 8: ...to off timer 2 0 0x7FFF 1s 0 0 Disable auto off function 1 0x7FFF 1s 32767s 9 RF off com mand mode 1 0 3 0 0 Switch off 1 Ignore 2 Switch toggle 3 Switch on 10 Edge or Pulse mode or Edge Toggle mode 1 1 3 1 1 Edge mode 2 Pulse mode 3 Edge Toggle mode 11 Manual Switch Report mode 1 0 1 1 0 Disable 1 Enable 14 Watt differential report mode 1 0 4 1 0 Disable 1 5 2 10 3 15 4 20 3 1 Watt Meter Report P...

Page 9: ...One Flash mode When the state of switch changes LED will be on only one second then LED keeps off 3 8 Auto off timer Whenever PAN03 PAN10 switches to on the auto off timer begin to count down After the timer decrease to zero it will switch to off automatically However if Auto off timer is set as 0 the auto off function will be disabled The default setting is 0 3 9 RF off command mode Whenever a sw...

Page 10: ...otection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN03 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by co...

Page 11: ...erature 0 C 40 C Frequency Range PAN03 1 868 40MHz 869 85MHz EU PAN03 2 908 40MHz 916 00MHz USA Canada PAN03 3 922 5MHz 923 9MHz 926 3MHz Taiwan JP PAN03 IL 916 00MHz Israel PAN10 1 868 40MHz 869 85MHz EU PAN10 2 908 40MHz 916 00MHz USA Canada PAN10 3 922 5MHz 923 9MHz 926 3MHz Taiwan JP PAN10 IL 916 00MHz Israel Specifications are subject to change and improvement without notice FCC ID RHHPAN03 D...

Page 12: ...equency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try...

Reviews: