3-3 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 1100, when the load current of Relay1 over this value,
PAN03/PAN10 will send current meter report to warn the Group1 node, the Range
of the setting value is from 10 to 1100, and the default value is 1100.
3-4 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, if the
setting value is 10000, when the Accumulated Power Consumption of Relay1
over this value, PAN03/PAN10 will send KWH meter report to warn the Group1
node, minimum value is 1KWh and default value is 10000 kWh.
3-5 Restore switch state mode:
Whenever the AC power return from lost, PAN03/PAN10 will restore the switch
state which could be SWITCH OFF
、
LAST SWITCH STATE
、
SWITCH ON. The
default setting is LAST SWITCH STATE.
3-6 Manual On/Off Mode:
The On/Off function of S1
、
S2 and learn switch can be disabled or enabled by this
parameter, default value is Enable. But the learning operation won’t be affected.
When manual On/Off function is disabled, the RF command can only switch On
but not Off. This is useful function for keeping the device in switch on state.
3-7 LED indication mode:
3-7-1 Show Switch State
:
When switch is on, LED is on. When switch is off, LED
is off. The default setting is Show Switch State.
3-7-2 Show Night mode
:
When switch is on, LED is off. When switch is off, LED
is on.
3-7-3 One Flash mode
:
When the state of switch changes, LED will be on only
one second, then LED keeps off.
3-8 Auto off timer
:
Whenever PAN03/PAN10 switches to on, the auto off timer begin to count down.
After the timer decrease to zero, it will switch to off automatically. However if Auto
off timer is set as 0, the auto off function will be disabled. The default setting is 0.
3-9 RF off command mode
Whenever a switch off command, BASIC_SET
、
BINARY_SWITCH_SET
、
SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.
3-9-1 Switch Off
:
It switches to OFF state. The default setting is Switch Off.
3-9-2 Ignore
:
The switch off command will be ignored.
3-9-3 Switch Toggle
:
It switches to the inverse of current state.
3-9-4 Switch On
:
It switches to ON state.
3-10 Edge mode
、
Pulse mode and Edge-Toggle mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle
mode, default value is Edge mode. But this parameter is useless to PAN10.
3-10-1 Edge mode: this mode is suitable for the bi-stable wall switch that has indica-
tor point on the switch, and the same position correspond to same state of re-
lay1. If the PAN03/PAN10 relay change the state because of receiving Z-
Wave RF command, it may need two times of change (switch on to off or
switch off to on) to let relay back to the correspond state. Manual switch S2 is
disabled in this mode.
3-10-2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the
state of Relay1.
3-10-3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch,
whenever change the state of the wall switch will also swap the state of Re-
lay1.
3-11 Manual Switch Report mode :
9