Warning: 

1.Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating. 

3. Do not use Non-Dimmable LED lamps.

 

 

 

 

Disposal   

 

This marking indicates that this product should not be disposed with other 
household wastes throughout the EU. To prevent possible harm to the 
environment or human health from uncontrolled waste disposal, recycle it 
responsibly to promote the sustainable reuse of material resources. To 
return your used device, please use the return and collection systems or 
contact the retailer where the product was purchased. They can take this 
product for environmental safe recycling.

 

Company of License Holder

Philio Technology Corporation 

Address of License Holder

8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 

24257, Taiwan(R.O.C)

 

 

 

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules.   

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation.   

This equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to 

radio communications.   

However, there is no guarantee that interference will not occur in a particular installation.   

If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one of the following measures:

 

• 

Reorient or relocate the receiving antenna.

 

• 

Increase the separation between the equipment and receiver.

 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

 

• 

Consult the dealer or an experienced radio/TV technician for help. 

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) This device must accept any interference received, including interference that may cause 

undesired operation. 

FCC Caution: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment. 

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter. 

 

 

 

 

 

 

 

 

Summary of Contents for PAD07

Page 1: ...ith a Secured enabled controller to fully utilize the device Its functionality and supported command classes is identical when included as a secure and non secure device Adding to Z WaveTM Network In the front casing there is an on off button also an include button with LED indicator below which is used to dim on and off or carries out inclusion exclusion reset or association When first power appl...

Page 2: ...wo groups for the dimmer Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LED Indication Normal Whenever we switch On an...

Page 3: ...l Switch Set Value 1 99 Duration 0 255 the attached load dim on as the level 1 Z Wave s Groups The Switch can be set to send reports to associated Z Wave devices It supports one association group with five nodes support for grouping 1 For group 1 the dimmer will report MULTILEVEL_SWITCH_REPORT ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION 2 1 Grouping 1 Lifeline Maximum 5 nodes 2 1 1 Device r...

Page 4: ...rkest level and so on 3 3 2 Two switch mode S1 and S2 can dim up the light bulb to brightest level then dim down to darkest level and so on 3 3 3 Up Down switch mode S1 can only dim up the light bulb to brightest level and S2 can only dim down to Off 3 4 restore dimmer state Whenever the AC power return from lost PAD07 will restore the switch state which could be Dimmer off Last dimmer state Dimme...

Page 5: ... 120V 100W 13W x 15 pieces Dimmable LED bulbs 120Vac Output Rating Maximum Dimmable LED bulbs Maximum 15 pieces Dimmable LED bulbs Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU PAD07 EU 908 4MHz 916 0MHz USA PAD07 US RF Maximum Power 5dBm Transmission Range Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject ...

Page 6: ...lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by t...