Philio PAD07 Quick Start Manual Download Page 5

 

 

Troubleshooting               
                   

 

Symptom

 

Cause of Failure

 

Recommendation

 

The dimmer does not 
work and LED off

 

1.The dimmer does not 

connect the electrical wire 
properly 

2.The dimmer break down

 

1.  Check power connections 
2. Don’t open up the dimmer and send it for 

repair.

 

The dimmer LED 
illuminating, but cannot 
control the ON/OFF 
state of the load 
attached

 

Check if the load 

connected to the dimmer 
has its own ON/OFF 
switch

 

Set the ON/OFF switch of the load attached 
to ON 
 

The dimmer LED 
illuminating, but the 
Detector cannot control 
the Switch

 

1. Not carry out association 
2. Same frequency 

interference

 

1. Carry out association 
2. Wait for a while to re-try

 

 
 
 
 
 
 
 
 
 

Specification 
 

Input Rating:(Operating Voltage)

 

100~240Vac / 50Hz~60Hz

 

Input Rating:(Operating Current)

 

0.01~1A ; (Maximum: 1A)

 

Output Rating: Maximum Load (Current)

 

Maximum: 0.9A (100~240Vac)

 

Output Rating: Maximum Load 
(watts)(230V)

 

200W (13W x 15 pieces) (Dimmable LED bulbs) 
(230Vac) 

 

Output Rating: Maximum Load 
(watts)(120V)

 

100W (13W x 15 pieces) (Dimmable LED bulbs) 
(120Vac) 

 

Output Rating: Maximum Dimmable LED 
bulbs 

 

Maximum: 15 pieces (Dimmable LED bulbs)

 

Operating Temperature

 

0°C ~ 40°C

 

Frequency Range

 

868.40MHz & 869.85MHz/ EU (PAD07-EU);   
908.4MHz & 916.0MHz/ USA (PAD07-US);

 

RF Maximum Power

 

+5dBm 

 

Transmission Range

 

Minimum 40 m in door 100m outdoor line of sight

 

Modulation Type 

 

FSK (Frequency-Shift Keying)

 

** Specifications are subject to change and improvement without notice.                           

 

           

FCC ID : RHHPAD07

 

 
 

 

 

 

 

Warning:    Do not use Non-Dimmable LED lamps.

 

 

 

DANGER

 

     

Danger of electrocution!

 

All works on the device may be performed only by a qualified and licensed electrician. 

Observe national regulations.   

Any works introducing changes into the configuration must be always performed with 

disconnected voltage.   

Choosing a Suitable Location 

1. Do not locate the Module facing direct sunlight, humid or dusty place. 

2. The suitable ambient temperature for the Module is 0°C~40°C. 

3. Do not locate the Module where exists combustible substances or any source of 

heat, e.g. fires, radiators, boiler etc. 

4.  After  putting  it  into  use,  the  body  of  Module  will  become  a  little  bit  hot  of  which 

phenomenon is normal. 

 

 

Summary of Contents for PAD07

Page 1: ...ith a Secured enabled controller to fully utilize the device Its functionality and supported command classes is identical when included as a secure and non secure device Adding to Z WaveTM Network In the front casing there is an on off button also an include button with LED indicator below which is used to dim on and off or carries out inclusion exclusion reset or association When first power appl...

Page 2: ...wo groups for the dimmer Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LED Indication Normal Whenever we switch On an...

Page 3: ...l Switch Set Value 1 99 Duration 0 255 the attached load dim on as the level 1 Z Wave s Groups The Switch can be set to send reports to associated Z Wave devices It supports one association group with five nodes support for grouping 1 For group 1 the dimmer will report MULTILEVEL_SWITCH_REPORT ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION 2 1 Grouping 1 Lifeline Maximum 5 nodes 2 1 1 Device r...

Page 4: ...rkest level and so on 3 3 2 Two switch mode S1 and S2 can dim up the light bulb to brightest level then dim down to darkest level and so on 3 3 3 Up Down switch mode S1 can only dim up the light bulb to brightest level and S2 can only dim down to Off 3 4 restore dimmer state Whenever the AC power return from lost PAD07 will restore the switch state which could be Dimmer off Last dimmer state Dimme...

Page 5: ... 120V 100W 13W x 15 pieces Dimmable LED bulbs 120Vac Output Rating Maximum Dimmable LED bulbs Maximum 15 pieces Dimmable LED bulbs Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU PAD07 EU 908 4MHz 916 0MHz USA PAD07 US RF Maximum Power 5dBm Transmission Range Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject ...

Page 6: ...lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by t...

Reviews: