background image

 

to the instructions for your Z-Wave

TM

 

Certificated Primary Controller to access the 

Setup function, and to Add/Remove/associate devices 

 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

LED 2-second on, 2-second 
off

 

Add (Inclusion)

 

1.  Put your Z-Wave controller into 

inclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.    Pressing Include button of PAD07 

three times within 2 seconds will 
enter inclusion mode.

 

Remove 
(Exclusion)

 

1.  Put your Z-Wave controller into 

exclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.  Pressing Include button of PAD07 

three times within 2 seconds will 
enter exclusion mode.

 

3. Node ID has been excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Reset

 

1.  Pressing Include button of PAD07 

three times within 2 seconds will 
enter inclusion mode.

 

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable.

 

2.  Within 1 second, press Include button 

of PAD07 again for 5 seconds.

 

3.  IDs are excluded.

 

0.5s On, 0.5s Off (Enter 
auto inclusion)

 

Association

 

1.  The PAD07 is an always listening 

Z-Wave device, so associations may 
be added or removed by a controller 
at any time. 

Or    If your controller requires to have 

the PAD07 send a 'node information 
frame' or NIF for associations, then 
pressing the On/Off button three 
times within 2 seconds will cause 
the PAD07 to send its NIF.

 

 

2.   

There are two groups for the dimmer.

   

Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node 
ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 

LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification. 
 

State Type

 

LED Indication

 

Normal

 

Whenever we switch On and off of the PAD07 by On/Off button or RF 
command, the LED will lights up when switch on; whereas LED off 
when switch off.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second intervals. 
By pressing On/Off button, it will stop flashing temporarily.

 

Learning

 

When PAD07 is in learning mode, LED flashes on and off alternately 
and repeatedly at 0.5 second intervals.

 

 

Choosing a Suitable Location 

1.  Do not locate the dimmer facing direct sunlight, humid or dusty place. 

2.  The suitable ambient temperature for the Switch is 0°C~40°C. 

3.  Do not locate the dimmer where exists combustible substances or any source of 

heat, e.g. fires, radiators, boiler etc. 

4.  After putting it into use, the body of dimmer will become a little bit hot of which 

phenomenon is normal. 

 

Manual dim level control :

 

To manually switch on the light, press and release the On/Off button or S1/S2 shortly 

when the light is off. The light will dim from off to the level which was set before switch 

off. To manually switch off the light, press and release the On/Off button or S1/S2 

shortly when the light is on. To adjust the dim level, press and hold the On/Off button 

or S1/S2 until the desired dim level is achieved, then release.   

 

 

Summary of Contents for PAD07

Page 1: ...ith a Secured enabled controller to fully utilize the device Its functionality and supported command classes is identical when included as a secure and non secure device Adding to Z WaveTM Network In the front casing there is an on off button also an include button with LED indicator below which is used to dim on and off or carries out inclusion exclusion reset or association When first power appl...

Page 2: ...wo groups for the dimmer Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LED Indication Normal Whenever we switch On an...

Page 3: ...l Switch Set Value 1 99 Duration 0 255 the attached load dim on as the level 1 Z Wave s Groups The Switch can be set to send reports to associated Z Wave devices It supports one association group with five nodes support for grouping 1 For group 1 the dimmer will report MULTILEVEL_SWITCH_REPORT ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION 2 1 Grouping 1 Lifeline Maximum 5 nodes 2 1 1 Device r...

Page 4: ...rkest level and so on 3 3 2 Two switch mode S1 and S2 can dim up the light bulb to brightest level then dim down to darkest level and so on 3 3 3 Up Down switch mode S1 can only dim up the light bulb to brightest level and S2 can only dim down to Off 3 4 restore dimmer state Whenever the AC power return from lost PAD07 will restore the switch state which could be Dimmer off Last dimmer state Dimme...

Page 5: ... 120V 100W 13W x 15 pieces Dimmable LED bulbs 120Vac Output Rating Maximum Dimmable LED bulbs Maximum 15 pieces Dimmable LED bulbs Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU PAD07 EU 908 4MHz 916 0MHz USA PAD07 US RF Maximum Power 5dBm Transmission Range Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject ...

Page 6: ...lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by t...