5
The Front panel will become hot when in use, to avoid
burns and scalds DO NOT TOUCH and keep children away.
This equipment has been designed to be used by adults.
So please make sure that children do not go near the
equipment or play with it, while the appliance is running.
Before carrying out any maintenance or cleaning of the
panel switch power supply off and let it cool down.
Installation
Bathroom Zones
The IP Rating indicates the amount of ‘Ingress Protection’ and refers to water/particle ingress.
The IP rating will determine where you can safely position your infrared heating panel.
Your infrared heating panel has been specially protected against the ingress of moisture and
is manufactured to meet IP44 standards, thereby making it suitable for installation in Zone 2
and 3 of your Bathroom.
Any electrical item approved for use in a zone may be used in another zone with a higher
number, but not in a lower number zone.
You MUST ensure that your mains electricity supply is isolated before
commencing installation.
Zone 2
Zone 1
unzoned
ceiling
2.25m
0.6m
0.6m
2.4m
Zone 3
0.75m
Please Note:
Installation in bathrooms, en-suites or similar rooms must be installed by a
qualified electrician in accordance with IEE wiring regulations and conform to BS7671 and
Part P of the Building Regulations.
The information above is intended as a guide only. For detailed information, refer to the IEE
wiring regulations.