Copyright Phigment Technologies, 2014
6
5. Technical Information
5.1.
CONFIG.TXT
The following fields define the general operation of the adapter:
(Please note, the parameter names are
case sensitive
)
Parameter
Valid Values
Description
id
1-62
This selects the default lens id when no lens is
recognized or the ID sensor is disabled.
sensor
0, 1
0 – Disable the lens ID sensor
1 – Enable the lens ID sensor
focus
0, 1
0 – Disable the focus change sensor
1 – Enable the focus change sensor
profile
0, 1
0 – Globally disable lens profiles
1 – Enable lens profiles if enabled for the present
lens
cast
0, 1
0 – Globally disable lens cast correction
1 – Enable lens cast correction if enabled for the
present lens
threshF
1-255
This is a hidden value and is used to determine the
threshold on when a focus change operation is
detected. Typical values are 3 to 5.
display
0, 1, 2
What do the LEDs display while connected to USB:
0 – scrolling
1 – Currently detected lens id
2 – Track focus distance
register
1-10
When present this instructs the adapter to read the
attached lens identification data and store the data as
identification for the specified lens ID.
5.2.
STATUS.TXT
This file contains the current firmware version number and the lens serial number. Depending on
configuration parameters, some seemingly random numbers may be present after the serial number.
This data may be useful in troubleshooting.
5.3.
LENSINFO.DAT
This file contains the lens information for each lens programmed in to the adapter.
Adapters using the 6-bit identification mode contain 62 lens entries. Adapters using the ‘register’
module contain 10 lens entries and registration data.
6.
Troubleshooting