ON-LINE RACK
PH 9360 - PH 9301 .
3.9. Fault codes
Failure
Code.
Icon
Failure
Code.
Icon
Bus start failure
01
X
Battery SCR short circuited
21
X
Bus over
02
X
Inverter relay short circuited
24
X
Bus under
03
X
Charger short circuited
2a
X
Bus unbalance
04
X
Can communication fault
31
X
Inverter soft start failure
11
X
Parallel
output
current
unbalance
36
X
High Inverter voltage
12
X
Over temperature
41
X
Low Inverter voltage
13
X
CPU communication failure
42
X
Inverter output short circuited
14
X
Overload
43
Negative power fault
1A
X
Battery turn-on failure
6A
X
Inverter over current
60
X
PFC current failure in battery
mode
6B
X
Inverter waveform abnormal
63
X
Bus voltage changes too fast
6C
X