background image

G

N

D

G

N

D

G

N

D

G

N

D

MIC

Power adaptor port

Power switch

Wired defense zone

Built-in horn

GSM signal indicator

      

The host shall be installed in the center of the prevent site which could realize best 

receiving effect from all wireless detectors. Please note that keep the host away from large-

sized metallic objects and home appliances producing high-frequency interference; Meanwhile 

avoid steel-reinforced concrete and fire-proof doors.

 

Panel

 

schemes:

-5-

-6-

Z

1

Z

2

G

N

D

Z

3

Z

4

G

N

D

Z

5

Z

6

G

N

D

Z

7

Z

8

G

N

D

NO

   

+

-

+

-

Arm

/

Disarm

GSM anti-theft alarm controller

GSM anti-theft alarm controller

Alarm Host Installation

Power

 

indicator(light)

Arm indicator

Alarm indicator

SOS

LCD

Arm

Disarm

Dial-up key

SIM slot
TF slot
Wired siren port

 

wire connecting terminal

 

LCD

 

display

:

Z

O

N

1

Z

O

N

2

Z

O

N

3

Z

O

N

4

Z

O

N

5

Z

O

N

6

Z

O

N

7

Z

O

N

8

For NC connection

Wired accessories A

Positive

Negetive

Power supply

NC COM

NO

   

NC COM

For NO connection

Wired accessories B

Positive

Negetive

Power supply

Alarm icon

Clock/Defence

Status icon

Fire Alarm

SOS

Gas

Alarm

Hall 

Alarm

Window

Alarm

Balcony

Alarm

Locks
Alarm

Perimeter

 Alarm

Front of the host

Back of the host

Summary of Contents for CT-PG-100

Page 1: ...GSM anti theft alarm controller User manual App Store Android Scan here download and install APP QR code 99 8 DEFENSE ZONES...

Page 2: ...GSM anti theft alarm controller...

Page 3: ...ge Setting 19 Host Keypad Lock Setting 20 Host Timing Arm Disarm Enable Disable Setting 21 Host Timing Arm Disarm Setting 22 Host Reset Setting 23 Host Logs Inquires 3 4 5 7 8 9 9 9 9 9 10 10 11 11 12...

Page 4: ...d be coded with smart home appliance Arm and Disarm timing function Can store 6 groups of phone numbers when alarming system will make alarm call to these numbers automatically Can store 2 groups of S...

Page 5: ...3 Z4 GND Z5 Z6 GND Z7 Z8 GND NO Arm Disarm GSM anti theft alarm controller GSM anti theft alarm controller Alarm Host Installation Power indicator light Arm indicator Alarm indicator SOS LCD Arm Disar...

Page 6: ...talled apposite the transmitter the distance between them should not be more than 1 cm 3 After installation the indicator light flashes one second while opening the door which means installation is av...

Page 7: ...ration the host would make a tick sound and setting is finished Operating method press button 4 Coding of Remote Controller Setting In setup state input number 21 then press to confirm The host make a...

Page 8: ...sensor for zone would be invalid so think it over before deleting Operating method 25 LCD display 9 Alarm Type Setting 9 1 There are 4 Defense Types Detector alarm type is set to 0 This detector will...

Page 9: ...r Stay Arm Operating method 47 82 1 LCD display 10 Wireless Siren Coding Setting In setup state input 28 8 digit wireless siren coding then enter to confirm The host makes a tick sound and then a voic...

Page 10: ...dicates Delayed alarm time unit second Example Detailed operating of 5 seconds delayed alarm time for defense zone 05 Operating method 34 05 05 LCD display 13 Arm Time Delay Setting In setup status en...

Page 11: ...XXXX indicates the new 4 digit password Example change the system password to 1012 Operating 38 1012 LCD display 18 2Change Administrator Password In setup status use keypad to input 39 then input the...

Page 12: ...B XXYY AABB indicates disarming time hour and minute XXYY indicates arming time hour and minute Example set disarming to 8 20 and arming time to 20 30 Operating 42 0820 2030 LCD display 20 Host Timing...

Page 13: ...hen a voice prompts setting completed Default not send Operating 46 X X 1 indicates send X 0 indicates not send Example send out SMS to user s mobile phone Operating 46 1 LCD display 26 System Clock S...

Page 14: ...makes a tick sound and then a voice prompts setting completed Operating 49 Example Deleting the first SMS alarm phone number Operating 49 LCD display 29 Alarm Phone Number Setting In setup state ente...

Page 15: ...SOS Alarm 2 fire alarm 3 gas leak alarm 4 door lock alarm 5 hall alarm 6 window alarm 7 balcony alarm 8 perimeter alarm Example set defense zone 10 to be fire alarm type Operating 60 10 2 LCD display...

Page 16: ...ing completed Default level 6 Operating method 64 X X indicates volume level Example level 2 Operating 64 2 Note If the volume level is set 0 then no sound LCD display 35 Language Setting In setup sta...

Page 17: ...ace operation Press the pr set host account enter into Main Menu then user can operate the functions of disarm out arm stay arm dial back and monitor and so on Press the pr set host account enter Syst...

Page 18: ...m state Disarm Press key host releases prompt System disarmed Disarm indicator LED on all the defense zones enter into Disarm state Press key host releases prompt System armed Out Arm indicator LED on...

Page 19: ...voice alarm If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you answer the call you will hear the p...

Page 20: ...lephone numbers 3 Whether the detector signal is received or backup battery works 3 Sensor detection 1 Manually trigger the detector to check whether it make alarms as usual 2 Check batteries of all d...

Page 21: ...ing Function Setting Host Timing Arm Disarm Setting Host Reset Setting Host Logs Inquires System Clock Setting SMS Phone Number Setting LCD Backlight Time Setting Sound Volume Setting Language Setting...

Page 22: ...ence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reo...

Reviews: