LOTUS XS 230 V horizontal continuous mixer / Part 2 Overview, operation and service
Operation
5.9
Action in case of power failure
Figure 35: Disconnecting the power
supply
Disconnecting the power supply
1. Disconnect the power supply.
2. Have the power supply connection checked by an expert.
NOTE
Generally, the setting times of the materials to be
processed must be observed. (Pay attention to outside
temperature when doing so).
The guidelines of the material manufacturers have to be
observed regarding breaks.
1
Figure 36: Switching on the machine
after a power failure
NOTE
The machine is equipped with a restart interlock. In case
of a power failure, this must be started as follows.
3. Press the green "ON" pushbutton (1).
5.10
Measures in case of risk of frost
CAUTION
Damage by frost!
Water that expands on freezing inside the component can
cause serious damage.
Therefore:
Only install dry parts.
Carry out the following steps when the pump is not operating and
there is a danger of frost.
2
1
3
4
Figure 37: Disconnect water supply
1. Remove the water hose (1) from the water inlet (2).
2. Disconnect the water hose (3) from the water inlet at the mixing
tube (4).
3. Connect an air hose with an air compressor to the water inlet (2)
and use low pressure to blow the water manifold dry.
NOTE
Make sure that the water fully flows out of the water mani-
fold.