LOTUS XS 230 V horizontal continuous mixer / Part 2 Overview, operation and service
Operation
5.3.4.1 Connection of water from water tank
1
Figure 26: Pressure booster pump
Figure 27: Suction strainer complete
with filter screen
Item no. of pressure booster pump AV1000/1 (1): 00493686
The connected pressure booster pump ensures the required water
pressure of at least 2.5 bar.
NOTE
When working with water from the barrel, the inlet strainer
must be fitted with a filter screen (item no. 00136619)
(Bleed the booster pump)
NOTE
The booster pump must not run dry to avoid any damage!
5.3.5
Setting pressure reducer
1
Figure 28: Setting set for pressure
reducer
2
4
6
5
7
3
Figure 29: Setting pressure reducer
NOTE
The adjustment range of the pressure reducer is 1.9 bar at
maximum flow. The adjustment to 1.9 bar takes place at a
flow rate of 1,500 l/h.
1. Loosen the locking screw (2) of the pressure reducer.
2. Setting set for pressure reducer (1) to the pressure reducer (3)
connect.
Setting set for pressure reducer:
Item no. 00066242
3. Connect the water hose from the water network at the water inlet
(4).
4. Easily loosen the screw (5).
5. Adjust the pressure reducer by turning (6).
6. The set pressure can be seen on the scale (7).
7. Then tighten the screw (5) again.
8. Remove the setting set (1) and close the pressure reducer (3) with
the locking screw (2).
page 28 / 48