7 TRIM FLANGE ATTACHMENT
Position Flange (
7A
) on Valve (
7B
) with Drain Hole (
7C
) at the bottom. Place
Protective Washer (
7D
) on the short end of the reversible Retainer Sleeve (
7E
).
Screw Retainer Sleeve (
7E
) onto threaded section of the Stem and Bonnet (
7G
).
Tighten Retainer Sleeve (
7E
) by hand until Flange (
7A
) is snug to finished wall
surface. If the short end of the Retainer Sleeve (
7E
) is too short, reverse it to
use the longer end.
10 SPOUT INSTALLATION
Apply PTFE plumbers tape on both ends of Pipe Niple (
10A
) (not included).
Screw Pipe Niple (
10A
) into the elbow inside the wall and tighten with pipe
wrench. The Pipe Niple (
10A
) is to project 3
7
/
8
" to 4" from the finished wall.
Screw Tub Spout (
10B
) onto Pipe Niple (
10A
) and tighten until Spout is properly
positioned and flush to the finished wall.
9 SHOWER ARM INSTALLATION
Insert the end of Shower Arm (
9A
) through the Shower Flange (
9B
). Apply PTFE
plumber's tape to back end of Shower Arm (
9A
) according to manufacturer's
instructions. Screw the end of Shower Arm (
9A
) into pipe elbow inside the wall.
Slide Shower Flange (
9B
) tight to the wall.
11 ARM MOUNT & HOSE INSTALLATION
Screw Arm Mount (
11A
) into the end of Shower Arm (
11B
). Connect Hose (
11C
) into
the Arm Mount Outlet (
11D
) by turning Metal Hose Fitting (
11E
).
8 HANDLE ATTACHMENT
Screw Stem Extender (
8A
) onto the Valve Stem (
8B
). Thread the Set Screw (
8C
)
into the Handle (
8D
) and thread it in only three to four turns. Place Handle (
8D
)
onto the Stem Extender (
8A
) and tighten the Set Screw (
8C
) by using the Hex
Wrench (
8E
) that is provided.
Make sure Set Screw (
8C
) is securely tightened to handle (
8D
)
.
3
7A
9A
7B
7C
7C
7D
7E
7G
9B
10A
3
7
/
8”
to 4
”
10B
8A
8B
8C
8D
8E
11A
11B
11C
11D