Your Rota-Loo has been built carefully to high standards and is warranted for ten years (supplied part

only) against original factory imperfections in materials and workmanship, to the original purchaser, under

normal home, holiday home, trailer, boat, commercial or industrial use as described, with respect to 

capacities in our literature. Electrical parts are warranted for one year or as specified by the manufacturer 

or supplier of the part.

Rota-Loo Capacity

 

PFG Group Victoria Pty Ltd will furnish new or rebuilt parts, for any part that fails within the warranty 

period, provided that our inspection shows such failure is due to defective materials or workmanship. Any 

part supplied by us to replace another part is warranted for the balance of the original period. 

PFG Group Victoria Pty Ltd or its Distributor will provide labour reimbursement for replacement of 

defective parts during the first ninety (90) days of purchase.

THIS WARRANTY DOES NOT COVER

:

1.  Damage resulting from neglect, abuse, accident or alteration; or damage caused by fire, flood, acts of 

God, or any other casualty.

2.  Parts and accessories not sold by PFG Group Victoria Pty Ltd, or damage resulting from the use of 

such items.

3.  Work carried out by persons not authorised by PFG Group Victoria Pty Ltd.

4. 

Damage

 or failure resulting from failure of the purchaser to follow proper installation and operating 

procedures as outlined in the Installation Manual and Operation Manual or other printed instruction.

5.  Labour, traveling and services charges incurred in the removal and replacement of any parts found 

under the terms of this Warranty.

This warranty is in lieu of all other warranties expressed or implied and no person is authorised to enlarge

our warranty responsibility, which is limited to the terms of this certificate. The Company reserves 

the right to change, improve, or modify its products and to install these improvements on equipment 

previously manufactured.

We need to record where your Rota-Loo is situated.

Please return the warranty registration card with your details within seven days of receiving 

your Rota-Loo to validate the Warranty.

Model

Number of Bins

Full Time Users

RL650

6

Up to 4

RL950

6

Up to 8

RL2000

8

Up to 20

Summary of Contents for Rota-loo RL950

Page 1: ...RL950 Owners Manual Compostable Batch Cycle Toilet System Proudly manufactured in Australia by PFG Group Victoria 87 93 Tramway Road Morwell Victoria 3840 www rotaloo com au...

Page 2: ...546 2 PFG Group Victoria Pty Ltd is a Quality Assured company certified as compliant to ISO9001 2015 AS NZS 1546 2 2008 is the Standard that sets out the requirements for the design and performance of...

Page 3: ...omposition it is important to keep the moisture containment of the material below 70 and ideally between 50 and 60 As fecal matter is 70 80 moisture and urine about 95 for a WCT to work correctly ther...

Page 4: ...he Rota Loo is sufficient to evaporate the liquid that has collected in the base of the Rota Loo chamber note that the design of the Rota Loo has the inlet vent low and opposite the outlet to promote...

Page 5: ...quired materials and tools Pages 7 to 10 highlight your installation instructions Installation of the Rota Loo involves Positioning the Pedestal and Rota Loo to ensure a vertical drop from the pedesta...

Page 6: ...Rota Loo The Waste Chute supplied allows for 800mm from the base of the Pedestal to the top of the Rota Loo but additional Waste Chutes may be added to increase this if desired Don t plan to install a...

Page 7: ...lter needs to be located lower than the Pedestal otherwise you will draw air from the toilet cubicle rather than where the air inlet is located To draw warm air down from ceiling cavities typically re...

Page 8: ...ste Chute you will give yourself room to install the Waste Chute as well as minimise the visual impact when you happen to look down the Pedestal Check you have clearance in the joists for the waste ch...

Page 9: ...from movement due to minor floods or storms now is the time to do this Install the Air Vent Piping The Rota Loo 950 has 4 vent pods molded into the main body Two of these will be used for the air ven...

Page 10: ...everything is in place the Rota Loo structure should be well insulated so that the temperature inside the unit remains as warm as possible This is particularly important in cold climate areas Please u...

Page 11: ...see if there is any bowing in the lid around the waste chute entry Make any adjustments required When the Rota Loo has been finally installed you will need to attach the waste chute to the joists or a...

Page 12: ...balance An outline of common problems and remedies are listed in the Manual When emptying the Bin use gloves eye protection and a dust mask to protect yourself from any residual pathogens that may ex...

Page 13: ...the Rota Loo any burning materials such as cigarettes or matches disposable nappies tampons wet wipes or sanitary napkins plastic rubber metal or glass material vegetable scraps fruit scraps or meat...

Page 14: ...date composting may not be complete and it is advised that the bin be removed and allowed to compost longer spare bins and lids are available for this purpose Additional bins must be fitted with a lid...

Page 15: ...e Rota Loo tank is not blocked and that the liquid flows out 3 Check the fan is operating 4 Unscrew the condensate cap and clear of any liquid or materials Salt Build Up Over a period of time dependin...

Page 16: ...ed or an excess liquid handling system should be constructed If the turntable won t rotate Check for obstructions On the RL650 the bins are quite close to the chamber sides and it may be that a bin ha...

Page 17: ...ic rate of aerobic bacteria therefore increasing the compost rate and producing less gases to attract the flies It is also recommended that a pyrethrum natural insect repellent spray or powder be adde...

Page 18: ...nusual situations The manufacturers contact details are included on the serial number plate for contact in unknown situations Storage of and access to Uncomposted Material Being fully self contained a...

Page 19: ...lking Material is Fed in While the addition of bulking material is recommended it is not essential for effective composting The use of toilet paper and the design to drain the compost pile of moisture...

Page 20: ...n provides for a factor of safety in time for composting In the case of very high use when compost may be removed before the designed 12 months instructions stipulate storing in additional bins Operat...

Page 21: ...ve and is recommended RL650 and RL950 Lids can be removed from outside the unit ROTA LOO WARRANTY We stand by our product and provide as much support as we can The Rota Loo and associated products are...

Page 22: ...use accident or alteration or damage caused by fire flood acts of God or any other casualty 2 Parts and accessories not sold by PFG Group Victoria Pty Ltd or damage resulting from the use of such item...

Page 23: ...complete with power lead Accessories RL650 950 filter pack of 6 filters 1 litre bottle of bio stimulant Any optional items ordered will be shown on the batch release picking list Items and Materials n...

Page 24: ...900 Use gloves eye protection and a dust mask to protect yourself from any residual pathogens that may exist Bury under 300mm of soil for 3 months or as required by your local authority If contact is...