Display
Designations
Func-
tions
Data
type
Access
type
Unit min. max.
de-
fault
326 TempElec
Electronics temperature
1
R
°C
0
999999
346 TempMotor
Motor temperature
1
R
°C
0
999999
349 ElecName
Electronic drive unit designa-
tion
4
R
360 ErrHist1
Error code history, item 1
4
R
361 ErrHist2
Error code history, item 2
4
R
362 ErrHist3
Error code history, item 3
4
R
397 SetRotSpd
Set rotation speed (rpm)
1
R
rpm
0
999999
398 ActualSpd
Actual rotation speed (rpm)
1
R
rpm
0
999999
399 NominalSpd
Nominal rotation speed (rpm)
1
R
rpm
0
999999
Tbl. 10:
Status requests
7.4 Reference value inputs
#
Indicator
Designations
Func-
tions
Data
type
Ac-
cess
type
Unit min.
max.
de-
fault
707 SpdSVal
Set value in rotation speed
setting mode | SmartVane 55
2
RW
%
60
100
100
Set value in rotation speed
setting mode | SmartVane 70
2
RW
%
45
100
100
717 StdbySVal
Set value for rotation speed in
stand-by | SmartVane 55
2
RW
%
60
100
80
Set value for rotation speed in
stand-by | SmartVane 70
2
RW
%
45
100
60
721 SlgVlvTime
Opening interval of gas ballast
valve
2
RW
min
0
60
5
730 Press. Set
Switch-on threshold with auto
standby / target pressure with
pressure regulation
10
RW
hPa
0.01
30.0
10.0
732 Press. Rel
Switch-off threshold with auto
standby
10
RW
hPa
1.0
100.0
20.0
739 PrsSn1Name Name sensor 1
4
R
740 Pressure 1
Pressure value 1
10
RW
hPa
1 · 10
-5
1200.0
742 PrsCorrPi 1
Correction factor 1
2
RW
0.1
8.0
-
797 RS485Adr
RS-485 Interface address
1
RW
1
255
2
Tbl. 11:
Reference value inputs
Parameter set
37/68