Indicator
Designations
Functions
Data
type
Ac-
cess
type
Unit min. max. de-
fault
024 Cfg DO1
Output DO1
configuration
0 = Switch-point reached
1 = No error
2 = Error
5 = Set rotation speed
reached
6 = Pump on
9 = Always "0"
10 = Always "1"
11 = Remote priority active
7
RW
0
21
2
026 SpdSet-
Mode
Rotation speed
setting mode
0 = off
1 = on
7
RW
0
1
0
034 Auto start
automatic start
after power fail-
ure
0 = off
1 = on
0
RW
0
1
1
052 BalGasValv
Gas ballast
valve control
(Not supported)
0 = off
1 = on
0
RW
0
1
0
060 CtrlViaInt
Operate via in-
terface
1 = remote
2 = RS-485
255 = Unlock interface se-
lection
7
RW
1
255
1
061 IntSelLckd
Interface selec-
tion locked
0 = off
1 = on
0
RW
0
1
0
063 Cfg DI2
Configuration
input DI2
0 - 4 = Deactivated
5 = Rotation speed setting
mode On
7
RW
0
5
0
095 FactorySet
Factory settings
1 = Reset to factory configu-
ration
0
RW
0
1
0
Tbl. 9:
Control commands
7.3 Status requests
#
Display
Designations
Func-
tions
Data
type
Access
type
Unit min. max.
de-
fault
300 RemotePrio
Remote priority
0 = no
1 = yes
0
R
0
1
303 Error code
Error code
4
R
304 OvTempElec Excess temperature drive
electronics
0 = no
1 = yes
0
R
0
1
308 SetRotSpd
Set rotation speed (Hz)
1
R
Hz
0
999999
309 ActualSpd
Actual rotation speed (Hz)
1
R
Hz
0
999999
310 DrvCurrent
Drive current
2
R
A
0
9999.99
311 OpHrsPump
Pump operating hours
1
R
h
0
999999
312 Fw version
Drive electronics software
version
4
R
313 DrvVoltage
Drive voltage
2
R
V
0
9999.99
314 OpHrsElec
Drive electronics operating
hours
1
R
h
0
999999
315 Nominal Spd
Nominal rotation speed (Hz)
1
R
Hz
0
999999
316 DrvPower
Drive power
1
R
W
0
999999
324 TempPwrStg Final stage temperature
1
R
°C
0
999999
Parameter set