Display
Designations
Functions
Data
type
Ac-
cess
type
Unit min. max. de-
fault
056 VentOnOff
Fan
0 = off
1 = on
valid only for pumps with
fan
0
RW
0
1
1
060 CtrlViaInt
Operate via in-
terface
1 = remote
2 = RS-485
4 = PV.can
32 = Keys on the front pan-
el
255 = Interface selection
7
RW
1
255
1
061 IntSelLckd
Interface selec-
tion locked
0 = off
1 = on
0
RW
0
1
0
095 FactoryRe-
set
Factory set-
tings
0 = no
1 = yes,
only possible while station-
ary
0
RW
0
1
0
no
Tbl. 9:
Parameter set | Control commands
7.3 Status requests
#
Display
Designations
Func-
tions
Data
type
Access
type
Unit min. max. de-
fault
303 Error code
Error code
4
R
309 ActualSpd
Actual rotational speed (Hz)
1
R
Hz
311 OpHrsPump
Pump operating hours
1
R
h
312 Fw version
Software version interface cir-
cuit board
4
R
313 DrvVoltage
Supply voltage
Voltage
in (V)
2
R
V
315 Nominal Spd
Nominal rotation speed (Hz)
1
R
Hz
316 DrvPower
Drive power
Output in
(W)
1
R
W
317 MotCurrent
Motor current
2
R
A
324 TempPwrstg
Temperature power electron-
ics
1
R
°C
342 TempOilL
Current oil temperature, float-
ing bearing side
Tempera-
ture (in
°C)
1
R
°C
343 TempExhGas
Current exhaust gas tempera-
ture
Tempera-
ture (in
°C)
1
R
°C
347 TempOilF
Current oil temperature, fixed
bearing side
Tempera-
ture (in
°C)
1
R
°C
349 ElecName
Device name designation
4
R
352 FWVERSDRV Firmware of the FC
4
R
354 HW Version
Hardware version interface
circuit board
4
R
360 ErrHist1
Error code history, item 1
4
R
361 ErrHist2
Error code history, item 2
4
R
362 ErrHist3
Error code history, item 3
4
R
363 ErrHist4
Error code history, item 4
4
R
Parameter set