20
Maintenance / replacement
7.2 Removal of components for their maintenance
In some cases, components may need to be dismantled from the pumping station
so that customers can carry out necessary maintenance work on them (they should
then be reassembled in reverse order).
Dismantling connec-
tions
Î
Switch off the pumping station at the master switch.
Î
Disconnect the mains plug.
Î
Remove the connector plug from the electronic drive unit.
Dismantling the
casing panels
The casing panels are fixed with quick release screws.
Î
Loosen four quick release screws from the casing cover.
Î
Remove the casing cover.
– Disconnect the earthing cable from the terminal socket of the casing cover.
Î
Lift the carrying handle.
Î
Loosen two retaining screws each from a side panel.
Î
Remove the side panel:
– Lift the side panel approx. 2-3 cm from its adjustment and tilt it outwards.
– Disconnect the earthing cable from the terminal socket of the side panel.
– Remove the side panel from the pumping station.
NOTE
Note the factory settings.
The accessory connections on the turbopump have been preconfigured at the factory.
If the control lines on the connector are mixed up, this can cause the pumping station
to malfunction or fail.
Î
Do not mix up the control lines.
Î
Accessory connections can be configured for operation with the DCU.
– For more information refer to the operating instructions for the electronic dri-
ve unit of the turbopump.
Fig. 9: HiCube Classic, dismantling the casing panels
11
Casing cover
78
Side panel 1
79
Side panel 2
78
7
9
11