CAUTION
Scalding from hot lubricant
Danger of scalding when draining lubricant if it comes into contact with the skin.
► Wear protective equipment.
► Use a suitable collection receptacle.
NOTICE
Property damage from using non-approved lubricant
Attainment of product-specific performance data is not ensured. If non-approved lubricants are used,
all liability and warranty claims against Pfeiffer Vacuum are excluded.
► Use approved lubricant only.
► Use alternative, application-specific lubricants only following consultation with Pfeiffer Vacuum.
Pfeiffer Vacuum recommends determining the precise service life of the lubricant in
the first operating year.
The usable life may deviate from the reference value specified depending on thermic and
chemical loads, or due to penetrating process media in gear and bearing chambers.
Checking the fill level
The correct fill level is between the MIN/MAX markings or within the ring mark on the sight
glass.
Safety data sheets
You can obtain the safety data sheets for lubricants from Pfeiffer Vacuum on request, or
from the
Pfeiffer Vacuum Download Center
.
The lubricant type is specified on the rating plate
1. Please refer to rating plate of the vacuum pump for type and quantity of intended lubricant.
2. Only use the lubricant which was applied during initial installation.
– Contact Pfeiffer Vacuum if you want to use another type of lubricant.
Prerequisites
● Vacuum pump switched off and cooled
● Vacuum pump vented
Required consumables
● Lubricant
Required tools
● Allen key,
WAF 10
● Wrench,
WAF 19
Required aids
● Cleaning cloth
● Collection receptacle
● Funnel (optional)
Maintenance
42/62