Technical data and dimensions
45
13.2 Technical data
Table 1: Typical ultimate pressure according to PNEUROP
Parameter
BA 251
BA 501
Flange (in)
DN 63 ISO-F
DN 100 ISO-F
Flange (out)
DN 63 ISO-K
DN 100 ISO-K
Pumping speed at 50 Hz
250 m
3
/h
500 m
3
/h
Pumping speed at 60 Hz
250 m
3
/h
500 m
3
/h
Ultimate pressure with gas ballast
1 hPa
1 hPa
Ultimate pressure without gas ballast
5 · 10
-2
hPa
5 · 10
-2
hPa
Exhaust pressure, min.
Atmospheric pressure
Atmospheric pressure
Exhaust pressure, max.
1500 hPa
1500 hPa
Nominal rotation speed at 50 Hz
1500 min
-1
1500 min
-1
Nominal rotation speed at 60 Hz
1800 min
-1
1800 min
-1
Nominal rotation speed pump, 50 Hz
490 min
-1
345 min
-1
Nominal rotation speed pump, 60 Hz
490 min
-1
345 min
-1
Emission sound pressure level without gas bal-
last at 50 Hz
63 dB (A)
65 dB (A)
Emission sound pressure level without gas bal-
last at 60 Hz
63 dB (A)
65 dB (A)
Ambient temperature
12-40 °C
12-40 °C
Protection category
IP 55
IP 55
Rated power 50 Hz
11 kW
15 kW
Rated power 60 Hz
13 kW
18 kW
Mains requirement: voltage 50 Hz
230/400 (± 5%) V
400/690 (± 5%) V
Mains requirement: voltage 60 Hz
265/460 (± 5%) V
460 (± 5%) V
Switch
No
No
Mains cable
No
No
Shipping and storage temperature
-25-+55 °C
-25-+55 °C
Operating fluid
P3
P3
Operating fluid filling
17 l
45 l
Weight: with motor
570 kg
1100 kg
Cooling method, standard
Water
Water
Cooling water pressure
2000-10000 hPa
2000-10000 hPa
Cooling water temperature
10-30 °C
10-30 °C
Cooling water consumption
> 50 l/h
> 90 l/h
Temperature: Operating
80 °C
80 °C