32
Care and maintenance
Fig. 9 - 03
2
1
Fig. 9 - 04
1
2
9
.05
Emptying/cleaning the water bowl of the air fi lter/regulator
Switch off the machine.
Disconnect the air hose at the
air fi lter/regulating unit.
Emptying the water bowl
Water bowl
●
1
empties itself automatically
when the air hose is disconnected from
the air fi lter/regulator.
Cleaning the fi lter
Unscrew water bowl
●
1
and take out fi l-
ter
2
.
Clean the fi lter with compressed air
●
or with isopropyl-alcohol, part number
95
-
665735
-
91
.
Screw in fi lter
●
2
and screw on water
bowl
1
.
9
.04
Checking/regulating the air pressure
Check the air pressure on gauge
●
1
every
time before operation.
Gauge
●
1
must show a pressure of
6
bar.
Regulate this pressure if required.
●
To do so, pull knob
●
2
up and turn it accor-
dingly.
Summary of Contents for POWERline 2595 BASIC