Replace and Adjust the Thread Guide Plate
Requirement
The left inner edge (C) of the thread guide plate should be approximately 1.4 mm from the center of the needle
drop position (D) and the back inner edge (E) of the thread guide plate should be approximately
2.7 mm from the center of the needle drop position (D).
Adjustment
• Remove the needle plate.
• Loosen the fl at screw (A) and adjust the position of the thread guide plate (B).
• The left inner edge (C) of the thread guide plate should be approximately 1.4 mm from the center of the needle
drop position (D) and the back inner edge (E) of the thread guide plate should be approximately
2.7 mm from the center of the needle drop position (D).
• Tighten the fl at screw fi rmly.