13 - 48
1
102
Reversing
OFF - ON
OFF
113
Beep tone for section change
OFF - ON
OFF
114
Max. speed forwards at each
OFF - ON
OFF
pedal position
2
201
Machine configuration
1 - 2
1
1 = 3801-3/07, 3801-3/071
2 = 3801-11/071 (with tape feed)
202
Knee switch for section change
OFF - ON
OFF
(in the seam programs 3 -49)
203
Length of tape feed section (mm)
0 - 99
0
204
Length of prepared tape section (mm)
0 - 99
32
205
Tape speed during feeding
0 - 9
9
206
Tape speed during preparation
0 - 9
5
207
Tape speed during threading
0 - 9
0
208
Tape feed in knife
0.0 - 0.9
0.5
212
not speed variation with change of
OFF - ON
OFF
fullness
213
program interruption with pedal-position -2
OFF - ON
OFF
3
301
Position
0 - 127
0
"Needle point at top edge needle plate"
302
Position "take-up lever t.d.c."
0 -127
107
303
Position "needle lowered"
0 -127
60
304
Reversing position
0 -127
107
305
Placement stitch position
0 - 127
7
4
401
Delay time "lift foot" (s)
0.01 - 1.50
0.02
402
Start delay after "lower foot" (s)
0.01 - 1.50
0.15
403
Thread trimming time (s)
0.01 - 0.20
0.12
404
Time for cleaning thread monitor (s)
0.01 - 1.50
0.25
13
.08.03
List of parameters
The operator has free access to the "100" parameters. Parameters "200" – "800"
can only be changed after entering a code number and may only be changed by
authorised personnel.
Group
Parameter
Description
Setting
Set
range
value
Summary of Contents for 3801-11/071
Page 122: ...15 3 Circuit diagrams Version 01 09 05 91 191 495 95 Page 1 ...
Page 123: ...15 4 91 191 495 95 Page 2 Version 01 09 05 Circuit diagrams ...
Page 124: ...15 5 Circuit diagrams Version 01 09 05 91 191 495 95 Page 3 ...
Page 125: ...15 6 91 191 495 95 Page 4 Version 01 09 05 Circuit diagrams ...