29.4
Air filter/lubricator (fig. 7)
.
1
Water trap
For maximum water level see fig. 7.
.1 Drain bowl 5 daily.
.
2
Air filter
Note:
Clean filter, if working pressure of 6 bar is no longer reached.
.1 Disconnect compressed air.
.2 Unscrew bowl 5.
.3 Remove washer 7.
.4 Remove filter 8.
.5 Clean filter and bowl with
petrol.
.6 Blow out filter
from inside to outside
with compressed air.
.7 When re-assembling, check for correct seat of seal.
.8 Connect compressed air.