14
6
Switching on the machine
.1
Open compressed air on main feed tube.
.2
Open valve 1 (fig. 1).
.3
Check working pressure: 6 bar (pressure gauge 2).
.4
If necessary, carry out an additional regulation of the air pressure (regulating button 3.).
.5
Turn main switch 4 (fig. 2) to “1”:
- Key
lights up
(Emergency-stop button 5, fig 4 must be unlocked.)
.6
Press key
:
- Guide carriage is positioning in basic position.
- Keys
and
light up.
- Machine is operational for “manual operation”.
Note:
For “automatic working procedure” also press key
.
- Keys
and
light up.
.7
Press key
:
- Key
lights up
- Key
goes out.
- Machine is operational.
7
Switching off the machine
Set main switch 4 (fig. 3) at “0” and close valve 1 (fig. 1).
If for some reason the machine is to be switched off immediately,
press EMERGENCY-STOP button 5 (fig. 4).
Summary of Contents for 3568-12/12