Adjustment
89
12
.12.03
List of parameters
Gr
oup
P
arameter
Description
User level
S
et
ting range
S
et value
1
105
Seam start speed
B,C
300 - 1500
1000
110
Seam end speed
B,C
300 - 1500
1000
116
Soft start stitches
B,C
0 - 30
0
117
Speed for soft start stitches
B,C
30 - 1000
400
3
382
Switching threshold of the analog input for
the thread monitor
B,C
0 - 100
15
387
Output Ax (motor running) is activated
1 = with pedal 1D (motor running)
0 = with pedal 1 (lower presser foot)
B,C
0 - 1
1
4
407
Cable fault detection on speed control unit
1 = on; 0 = off
B,C
0 - 1
1
452
Input "operation lock"
1 = on; 0 = off (no function)
B,C
0 - 1
1
5
521
Needle position if sewing stop before seam end
1 = needle position "2" (take-up lever raised);
0 = needle position "1" (lowered)
B,C
0 - 1
1
538
Tacting output Ax (thread tension release)
0 = 100% power up
B,C
10 - 50
30
6
605
Actual value on display
1 = on; 0 = off
B,C
0 - 1
0
606
Speed level 1 (min.)
B,C
30 - 300
180
607
Speed level 2 (max.)
B,C
300 - 3500
2500
609
Cutting speed 1
B,C
60 - 300
180
615
End recognition with photo sensor
1 = from bright to dark;
0 = from dark to bright
B,C
0 - 1
1
618
Reversing after seam end
1 = on; 0 = off
B,C
0 -1
1
623
Switch on delay for reversing [ms]
B,C
0 - 2000
30
660
Bobbin thread monitoring
0= without monitoring
1 = with sensor
2 = with stitch counting
A,B,C
0 - 2
0