Adjustment
14 - 3
14
.06
Work clamp zero point
Requirement
After the machine ahs been switched on and parameter
"608"
selected,
1. the needle should be centred to the hole in the adjustment gauge,
2. the switch lugs
2
and
4
should be centred to the respective initiator.
When removing the work clamp holder, take care that the ball bearings in the
arm support do not drop out !
●
Remove the work clamp holder and the lower feed plate .
●
Screw adjustment gauge
1
(part no. 61-111 637-08) to the work clamp drive unit.
Preliminary adjustment
●
Move the work clamp drive unit by hand in accordance with
requirement 1
.
●
Adjust switch lug
2
(screw
3
) and switch lug
4
(screw
5
) in accordance with
requirement 2.
Fig. 14 - 02
4
5
2
3
1