Adjustment
14 - 32
000
017
Clamp solenoid
Operating time [10 ms]
5 – 100
10
The time, for which the solenoid is
under full current, is entered.
018
Clamp solenoid duty-cycle [%]
5 – 100
20
At the end of the clamp solenoid
operating time (Parameter "017") the
solenoid is clocked. The relationship
between duration of operation and
non-operation is entered here.
019
Thread trimming solenoid operating
time [10 ms]
5 – 100
25
The time, for which the solenoid is
under full current, is entered.
020
Thread trimming solenoid duty-cycle
5 – 100
100
At present without a function
021
Thread take-up lever t.d.c. [°]
45 – 53
51
The position for the t.d.c. thread
take-up lever is entered here. If the
function is executed, the position can
be set by turning the balance wheel.
The access code is necessary for this
adjustment.
022
Thread trimming position
(in relation to t.d.c. needle) [°]
180 – 253
180
The position, at which the thread
trimming solenoid is switched on, is
entered here. The adjustment is set
by turning the balance wheel.
The access code is necessary for this
adjustment.
023
Sewing area size X [1/10 mm]
±200
-100 / +200
To avoid mechanical collisions, the
sewing area size of the clamp in use
is entered. The control unit checks
the path and, if necessary, issues an
error message.
024
Sewing area size Y [1/10 mm]
±100
-15 / +15
To avoid mechanical collisions, the
sewing area size of the clamp in use
is entered. The control unit checks the
path and, if necessary, issues an error
message.
Group
Parameter
Description
Setting
Set value
range
Summary of Contents for 3371-1 series
Page 43: ...15 2 91 191 486 95 Page 1 Version 13 10 04 Circuit diagrams...
Page 44: ...15 3 Circuit diagrams Version 13 10 04 91 191 486 95 Page 2...
Page 45: ...15 4 91 191 486 95 Page 3 Version 13 10 04 Circuit diagrams...
Page 46: ...15 5 Circuit diagrams Version 13 10 04 91 191 486 95 Page 4...
Page 47: ...Notes...