Adjustment
11 - 11
11.
05.09
Needle in needle hole center
(only on PFAFF 1053 and 1183)
Requirement
The needle must penetrate the needle hole exactly in the middle.
●
Set the needle in the needle hole.
●
Loosen screws
1, 2
and
3
.
●
Move the needle bar frame
4
according to the
requirement.
●
Tighten screw
2
and turn screw
3
slightly.
●
Via screw
1
, bring the retracted guide bolt to the eye of the needle bar frame
4
and
tighten it.
●
Turn the handwheel a few times to prevent distortion to the needle bar frame
4
.
●
Tighten screw
3
.
3
2
1
4