- Loosen the lock nut of the rocker
adjustment screw. (3)
- By means of feeler gauges, adjust the
clearance of every valve by acting on the
rocker set screw.
Clearances:
• 15/100 at the intake
• 15/100 at the exhaust
- Immobilize the rocker set screw.
- Tighten the locknut without altering the
adjustment.
- Check the adjustment.