background image

 

23 

Transfer D500X firmware to CF card 
 
This selection transfers a firmware upgrade file from the PC to the CF card in order to 
upgrade the D500X firmware through a special procedure. Firmware upgrades are supplied by 
Pettersson as they become available. The upgrade file should have the extension “.D500X”. 
To upgrade, the firmware file should be transferred to the CF card using the Transfer function 
of the D500X Utility program (copying the upgrade file to the CF card through Windows will 
not work). Then put the card in slot #1 of the D500X and turn the power on with the 
EXT/INT Power switch. The detector will automatically recognize the card as a “firmware 
upgrade” card. Follow the instructions on the display to perform the upgrade. 
 
 
Recorded data files 
 
The Info command will display metadata from the selected file (file name, date/time and 
firmware version). 
 
The Clean file command will remove the extra information that is stored in the file. This 
information is stored at the beginning of the file and can be seen in the spectrogram or 
oscillogram as a very short transient. Usually, this transient is so short that it is not noticed. 
Please note that after using the Clean file command, the information erased from the file 
cannot be retrieved, so it is advisable to perform this operation on a copy of the original file. 
 
The File management command opens the File Management dialog box which gives a list of 
the D500X files in the selected drive/folder with the embedded file information: 
 
 

 

 
 

Summary of Contents for D500X

Page 1: ...o pre trigger i e the recording starts as the sound exceeds the chosen threshold level but both pre and post trigger functions are available in the standard not low power mode Some of the features of...

Page 2: ...customer s recovery from Pettersson for any claim shall not exceed the purchase price paid by the customer for the goods irrespective of the nature of the claim whether in warrant contract or otherwi...

Page 3: ...eate and file modified time in files changed to better represent the true time If the power is switched off or otherwise fails while the detector is in the Automatic Recording mode the detector will a...

Page 4: ...key is used to start recording or to enter the automatic recording mode depending on which mode was chosen The ON OFF key is used to switch the detector on off or to exit the sleep mode It is also use...

Page 5: ...erview Battery holders for 2 x 2 AA cells Built in electret microphone External microphone jack External power jack 5 5 8 V DC External trigger jack Power switch to select external or internal batteri...

Page 6: ...NPUT GAIN 45 TRIG LEV 36 INTERVAL 5 SAMP FREQ 500 PRETRIG 1 REC LEN 5 HP FILTER YES AUTOREC YES T SENSE VERY HIGH ENTER Use to switch between parameters and to change the values Press ENTER to save ch...

Page 7: ...IN Press the 1 0 key and then ENTER to enter standby ENTER ENTER Only for automatic recordings Manual recordings will start immediately after pressing REC For more detailed information about the funct...

Page 8: ...n Power switch is activated In order to constantly maintain power to the real time clock and some other parts of the detector a small lithium battery is incorporated in the detector After several year...

Page 9: ...ds will appear This may take a few tens of seconds depending on the size and number of CF cards Press ENTER to continue to the D500X READY screen First adjust the Input Gain volume control by pressing...

Page 10: ...ain should be adjusted to keep the dB indicator below its maximum reading The Trigger Level should be set to make the detector trigger start recording at the desired signal level As an aid to do that...

Page 11: ...ry high 0 High 1 Medium 2 Low 3 Very low 4 Switching between different profiles is an easy and fast way to change the settings The D500X has ten fixed profiles and ten user profiles To select which on...

Page 12: ...he plug connected to the External Trig input jack RECORDING SETTINGS The parameters in the recording settings menu are Input gain volume Trigger level Minimum time interval to the next recording The h...

Page 13: ...e the left right arrow keys to move between hour minute and the up down keys to change the value To accept and save the changes press ENTER If the Relative Timer is selected the calculated sunset and...

Page 14: ...GHTNESS The MODE parameter determines in which situations the display is on When the detector is left unattended there is no need to have the display on at all while in other situations it may be bett...

Page 15: ...ries If the battery voltage continues to decrease and falls below the shut down level the D500X will interrupt any recording in progress and put itself into sleep mode It then regularly monitors the b...

Page 16: ...using the D500X Utility program The preparation stage has been eliminated in firmware version 2 so this version only requires that the CF cards used have been FAT32 formatted as described above Cards...

Page 17: ...ing total space on all of the cards When the unit is set up for an automatic level triggered recording session all the CF cards should be newly formatted i e not contain any previous recordings The sw...

Page 18: ...t the settings 3 Press F1 and set the display operating mode in the DISPLAY menu The recommended modes for automatic recording are OFF or AUTO OFF will keep the display off during the entire recording...

Page 19: ...the indicators will flash once every second The detector will of course not respond to any sound as long as the current time is outside of the timer ON OFF interval 6 To end the recording session wake...

Page 20: ...e warning level factory defaults 4 0 V for internal batteries and 4 7 V for external batteries This allows the battery to recover before the detector is allowed to resume recording which is important...

Page 21: ...her installed the identification number is the serial number of the detector by default The metadata or parts of it can be retrieved by the D500X Utility program and the BatSound program Users upgradi...

Page 22: ...me files with optional adding of date time prefix suffix to the file name Transfer D500X firmware upgrade files to a CF card The first step in using the D500X Utility is to select the drive that has t...

Page 23: ...as a firmware upgrade card Follow the instructions on the display to perform the upgrade Recorded data files The Info command will display metadata from the selected file file name date time and firmw...

Page 24: ...r defined prefix and or suffix can be added to the original file name Selecting multiple files will create copies of all files with time date prefix and suffix added This is useful to add identificati...

Page 25: ...nal mic select input tie to pin B on plug to enable ext mic External batteries A Ground terminal B Positive terminal 5 5 8V The External DC jack accepts a DC voltage between 5 5 and 8 V 6 V recommende...

Page 26: ...r protected in the meaning that it will withstand dust and a certain degree of humidity Heavy rain may result in water intrusion so under such conditions additional protection is recommended The prote...

Reviews: