background image

SECTION 2.
THE COLLAR RECEIVER

The collar receiver is waterproof, rechargeable, and can
be mounted on any non-metal strap. The probes are
available in long and short lengths to be used on long-
haired and shorthaired dogs, respectively.

Note: The collar receiver is always on and ready to
respond to the containment field when the battery is
properly charged.

A.Special Features to Increase the Effectiveness of
the System 

1.The Warning Tone  - With the STIM LEVEL switch
set to LOW or MED your dog will hear a two second
warning tone when he reaches the edge of the contain-
ment field in the yard.If your dog does not return to the
safe part of the yard, he will receive a continuous cor-
rection (at the Low or Medium correction level switch
setting) until he re-enters the safe part of the yard.
Note: If the STIM LEVEL switch is set on HIGH, there
will be no warning tone prior to the correction.

2. Run-Through Prevention - Special features are
incorporated in the IF-100 system so your dog cannot
"run-through" the containment field without activating a
strong correction. The receiver automatically increases
the correction when your dog continues more than 1/3
of the way through the containment field, regardless of
the transmitter correction level setting. For example, if
the signal is detected 12 feet from the wire and your dog
enters the containment field, this feature is activated
when he is approximately eight feet from the wire. At
this point, your dog automatically receives the highest
level of correction for a minimum of three seconds.

3.Over-Correction Prevention - In the unlikely event
that your dog becomes "trapped" in the containment
field, this feature limits correction duration to 10 sec-
onds. The system shuts off for 10 seconds before
resuming correction for another 10 seconds. This pat-
tern will repeat for a maximum of three cycles, a dura-
tion of 60-seconds.

The light on the collar receiver will pulsate red when
correction is delivered, appear solid green when cor-
rection is loc ked out, and flash yellow if the 60-second
period has expired and the dog remains in the contain-
ment field.

B.Receiver Indicator Lights 

The receiver includes an indicator light and a tone gen-

erator that allow the user to distinguish the various
operational conditions of the receiver. These conditions
are summarized in the following table:

SECTION 3.
THE LIGHTNING PROTECTOR

Your system includes a lightning protection unit, which
helps  protect  the  transmitter  from  electrical  powe r
surges and lightning strikes near your boundary loop. A
nearby lightning strike can induce damaging high volt-
age on the boundary wire loop and electrical power
lines, which can damage an unprotected containment
transmitter. The lightning protector protects your sys-
tem in two ways. Lower level voltage spikes from near-
by lighting strikes and power line surges are sup-
pressed to a level that will not damage your transmitter.
Severe lightning strikes may result in damage to the
Lightning Protector, which is designed to be a sacrificial
link  in  the  system.

Your  transmitter  will  remain

u n h a rmed  and  your  Lightning  Protector  can  be
replaced under the terms of the Lightning Protector life-
time warranty (see Limited Warranty Section pg. 22).
System components which are not properly protected
by the supplied Lightning Protector will not be covered
for lightning damage under the warranty (see Limited
Warranty Section pg 22).Your Lightning Protector has a
green power light that indicates the unit is receiving
household power.

Note that this Lightning Protector is specifically designed for electronic dog
containment systems and will not protect other kinds of equipment against
lightning damage or AC surges.

INDICATOR LIGHT

GREEN FLASHING 

(ONCE EVERY SECOND)

GREEN PULSATING

RED PULSATING

RED FLASHING

(ONCE EVERY 2 SECONDS)

SOLID GREEN

YELLOW FLASHING (ONCE

EVERY 2 SECONDS)

NONE

CONDITION

COLLAR IS READY TO RESPOND 

TO THE CONTAINMENT FIELD

WARNING TONEIS OCCURRING

ENTRY LEVEL CORRECTION IS

BEING DELIVERED

RUN-THROUGH CORRECTION IS

BEING DELIVERED

RECEIVER BATTERY IS LOW

CORRECTION IS LOCKED OUT 

(OVERCORRECTION 

PREVENTION IN EFFECT)

OVER-CORRECTION 

PREVENTION HAS EXCEEDED 

THREE CYCLES ( S T I M U L ATION 

IS LOCKED OUT UNTIL YOUR DOG

RETURNS TO THE SAFE ZONE)

RECEIVER BATTERY IS 

COMPLETELY DISCHARGED

6.

TONE PITCH

NONE

INTERMITTENT 

LOW PITCH

INTERMITTENT 

MEDIUM PITCH

INTERMITTENT 

HIGH PITCH

NONE

CONTINUOUS 

LOW PITCH

NONE

NONE

Summary of Contents for IF-100

Page 1: ...ou begin training You want your dog to accept the collar as part of a routine not to associate the collar with the correction 10 To prevent the elimination of an adequate safe zone in your yard any adjustments to the field width must be tested prior to using the system with your dog Once the field width has been set and tested turning the knob in a clockwise direction will increase the correction ...

Page 2: ... with installation hard ware C One 24 volt 400 milliamp AC adapter to power the containment system D One lightning power surge protector E One test lamp for testing the collar receiver F One hundred boundary flags G Green insulated containment boundary wire 700 feet H White insulated pre twisted containment wires 100 feet I Interchangeable collar receiver probes for longhaired and shorthaired dogs...

Page 3: ... be sure the transmitter is turned on and check all connections After the receiver has been fully charged set the POWER switch to the OFF position remove the short piece of boundary wire and unplug the AC adapter from the wall outlet NOTE The transmitter will not recharge the collar receiver if the loop wire is not installed 4 Plan the Boundary Wire Placement See Section 4 D pg 9 for details For t...

Page 4: ...ith the collar receiver held at the height of your dog s neck with the probes pointed upward Listen for the warning sound and watch for the test light to illumi nate The containment field should extend at least 8 to 12 feet on each side of the wire To increase the field width rotate the FIELD WIDTH adjustment knob clock wise and recheck the distance the signal is broadcast ing from the wire To dec...

Page 5: ... on the backside of the transmitter housing Only use Alkaline batteries The Battery Backup Monitor will sound to indicate the AA batteries need to be changed This alarm can be turned ON or OFF by the switch inside the transmitter For the safety of your dog this feature should be turned on and the batteries kept in working order at all times 8 Wire Terminals The two containment loop wires from the ...

Page 6: ... B Receiver Indicator Lights The receiver includes an indicator light and a tone gen erator that allow the user to distinguish the various operational conditions of the receiver These conditions are summarized in the following table SECTION 3 THE LIGHTNING PROTECTOR Your system includes a lightning protection unit which helps protect the transmitter from electrical power surges and lightning strik...

Page 7: ...r the front or back yard This layout is similar to the perimeter loop except the wire is run close to the house on two sides When positioning the wire parallel to itself as it goes toward the side of the house from the perimeter keep it a distance equal to the field width plus three feet from itself To prevent your dog from playing in the side yard keep the wire a distance equal to the field width...

Page 8: ...set the GFCI to restore household power to the system If you must use a GFCI protected outlet make sure you take advantage of the system s battery backup fea ture described in Step 3 of this procedure Also check the location where you want to bring the outside wires through the wall and into the wall transmitter to avoid electrical or tele phone wires television cables or water pipes Even after ch...

Page 9: ...he wall transmitter Orient the light on the collar receiver toward the end of the charging cradle marked with an arrow and identified on the label 5 Cut a short piece of the green boundary wire about 6 inch es long and strip about 3 8 inch of insulation from both ends Insert the wire ends into the LOOP terminals on the transmit ter NOTE This wire is temporarily installed to perform the ini tial se...

Page 10: ...he above recommendations may cause you to modify your layout but it will be time well spent When your layout is final ized place the wire around your property according to your diagram The wire loop should begin and end at a perimeter location closest to the location of the transmitter This will min imize the amount of twisted wire needed to connect the boundary loop wire to the transmitter DO NOT...

Page 11: ...wer Adapter Make sure the POWER switch on the transmitter is in the OFF position Plug the power adapter into the power outlet on the right side of the Lightning Protector Plug the other end of the power adapter into the POWER jack on the transmitter Place thepower cordwireunder the wireretentiontabon thehousing 6 Checking Out the Installation Make sure your dog is not wearing the collar and no one...

Page 12: ...here the wire first enters the ground near the transmitter and continue around the path of the loop wire A 30 to 45 angle cut made with a flat blade spade will be the easiest to close and heal Allow for slack in the wire throughout the boundary wire loop to compensate for expansion and contraction due to temper ature changes When covering a large area you may wish to use a lawn edger or trenching ...

Page 13: ...to function the transmitter must be plugged in turned ON and have boundary wire attached to the LOOP terminals on the transmitter By placing the receiver on top of the transmitter in the charge cradle with the receiver indicator light aligned toward the end of the charge cradle marked with an arrow a 14 hour battery charging cycle will be initiated During this 14 hour charging cycle the transmitte...

Page 14: ...ry 3 months to maximize battery life 9 Test the collar receiver in the containment field week ly to verify that the system is functioning properly To test hold the supplied test light to the collar receiver probes Holding the receiver by the case NOT by the probes walk into the containment field With the receiv er held at the height of your dog s neck with the probes facing upward verify the warni...

Page 15: ...ence training is To teach your dog to identify and retreat from the boundaries To make the training fair so your dog will understand the consequences of leaving the yard To make the training fun so your dog will enjoy stay ing and playing on your property This training plan is divided into four parts training equipment the schedule rules and routine and training lessons A Training Equipment You ll...

Page 16: ...use them as temptations Lesson 4 Off Lead Supervision After several sessions of distractions your dog should be ready for off lead play You must stay in the yard for off lead training In fact it s wise to spend more quality time in the yard with your dog The more your dog stays on the proper ty for the first month the less confused he will be If you wish to take your dog off the property remove th...

Page 17: ...fit is not tight enough to make good skin contact See Section 5 A page 12 2 Correction level too low Set the Correction level switch to the next higher level 3 Field width setting is not wide enough Increase the containment field width and re verify the detection distance See Section 4 G page 11 4 Remove any metal collars from the dog 5 Make sure any metal tags cannot contact the collar probes 6 A...

Page 18: ...undary wire connections at transmitter and lightning protection module for proper connection 2 Check for broken or damaged wires at outside entry into house 3 Perform Transmitter Loop Test Procedure to locate and correct the problem Section 8 A pg 19 4 Perform Wire Break Location Test Procedure and correct the problem Section 8 B pg 19 1 Verify the transmitter POWER switch is ON 2 Check that the a...

Page 19: ...ected operating on battery backup power 3 Receiver charging 4 Receiver charge reminder 5 Backup batteries low Possible Solutions 1 Verify the transmitter is turned on and the status light is solid green 2 Check the collar receiver for a green flashing indicator light If light is flashing red or there is no light recharge battery See Section 5 B 4 page 13 3 Perform the field width test of Section 4...

Page 20: ... or damaged sections of the containment bound ary wire To locate wire breaks in the loop installation you will need a portable AM radio and a RF Choke available at Radio Shack part number 273 102 Once you have these items follow these steps 1 Disconnect the transmitter power by unplugging the power adapter from the outlet 2 Disconnect the boundary wires from the Lightning Protector LOOP terminals ...

Page 21: ...acti vates 9 Turn the FIELD WIDTH adjustment knob to 10 o clock or a medium setting 10 Back away from the wire and approach it again Determine the distance between you and the wire when the collar activates The distance should be greater on the 10 o clock range setting than on the minimum set ting 11 If more than one collar receiver is used on the sys tem repeat the above test on each collar 12 In...

Page 22: ... to Invisible Fence the purchaser is urged to call 1 800 688 4364 to obtain instructions on returning com ponents This Limited Warranty extends to and is enforceable only by the original retail purchaser during the period such original purchaser resides at and owns and occu pies without interruption the real estate upon which the System is installed This Limited Warranty covers only the components...

Page 23: ...nce All rights reserved 2100202 23 IMPORTANT NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio fre quency energy and if not installed and us...

Page 24: ... electronic pet containment system wall mounted transmitters against damage from lightning Lightning Protector contains two protectors One stops lightning currents from entering through the loop wire the other stops lightning from enter ing through the AC power connection 2100156 ...

Page 25: ...n light does not illuminate recheck all connections NOTE Avoid using an AC outlet protected with a ground fault current interrupter GFCI The containment system and the Lightning Protector will function properly in a GFCI outlet but in rare cases lightning strikes may cause the GFCI to trip and you will have to reset it in order for your containment system to function prop erly 4 Cut the in ground ...

Page 26: ...tlet on the side of the Lightning Protector see diagram The AC adapter cord may be secured to the bottom of the Lightning Protector using the included wire tie Turn on the contain ment system If you have added the Lightning Protector to an existing containment system check the signal field for width and continuity Adjust as necessary If the Lightning Protector is being installed with a new system ...

Page 27: ... workmanship and that Invisible Fence will replace any defective unit and repair any unit that has suffered damage from a lightning surge or line overvoltage Note that this Lightning Protector is specifically designed for electronic dog con tainment systems and will not protect other kinds of equipment against lightning or AC surges There is no warranty for any equipment connected to this Lightnin...

Reviews: