4
Figure 3: Mounting pad attached to unit (sample installation)
1.3 General Device Installation, Operation and Data Management
Notes
The general process to be followed to configure, install, manage and export the data is
summarized as follows:
•
Using the utility software application, configure the SD memory card for initial
deployment.
•
Insert memory card into device.
•
Install GPS antenna-receiver on dash and route cable to area under dash.
•
Locate OBDII SAEJ1962F Diagnostic Link Connector (DLC) and plug in OttoView-CD
OBDII cable connector.
•
Insert vehicle ignition key and locate and place RFID antenna in best location that will
allow it to register the key fob tag.
•
Turn on vehicle ignition.
•
Attach each cable and observe that all LEDs are “ON”.
•
Complete installation of cables neatly using tie wraps.
•
Retrieve memory card and upload data to PC.
•
Export data to desired file format and review information collected.
1.4 OBDII Vehicle Interface Connection-Installation
Install the device in the vehicle within 1.5 m of the OBDII connector using the supplied
installation kit. The device comes complete with a cable that plugs into the vehicle’s OBDII
socket.
The OBDII port is located within 1 meter of the steering wheel, usually within the area
indicated by the dotted line in the illustration above. The connector can be easily accessed