10. - SET WINTER OR SUMMER MODE
2
Select with the
keys the item
StAG SET.
Confirm with
OK.
Select with the
keys the
(heating) or
WINTER
SUMMER
OK.
(cooling) mode and confirm with
From normal thermostat operation, access the menus by
pressing
the «
» key.
for 5 secs.
Mode
Press the «
» key to exit.
Mode
10. -
1
MODIFICATION OR DISABLING OF SET ANTIFREEZE TEMPERATURE
From normal thermostat operation, access the menus by pressing for 5 secs. the «
» key.
Mode
Item
SET TEMP Set
, confirm with
.
OK
The screen displays
SEt TEMP Set
Press 3 times the
key.
OK
Use the
keys to set the desired antifreeze temperature (default 6.0°c).
Every time the
keys are pressed, it changes by 0.1 degrees; pressing
or
and holding enables you to scroll through the values rapidly.
Range: +4 °C a +12°C
To disable antifreeze temperature go below
,
+4.0 °C
.
(39.2 °F)
disabled
antifreeze temperature
Confirm with
OK.
Press the «
» key
to exit.
Mode
twice
press 3 times
1°
/OK
2°
/OK
2°
or
/OK
default:
/OK
10 - USER MENU
35