3 seconds
3 seconds
3 seconds
In order not to use the MAINTENANCE function, set the counter to zero for channel C1 and/or C2
(dual-channel model).
Disabling the Maintenance function
«
»
9.4) HOUR COUNTER
This feature allows you to view and reset the count of operating hours in ON for channel 1 and/or channel 2
(dual-channel mod.). This is useful to monitor the life of the load/device connected to the channel.
1. From the
.
COUNTER
SET
sub-menu confirm with
OK
2. Use the
keys to select the desired channel from
or
(dual-channel model).
C1 C2
The operating hours of the selected channel will be displayed.
Reset the hour counter:
3. Use the
keys to select the desired channel from
or
(dual-channel model).
C1 C2
4.
(the number of the hour flashes):
Press the key corresponding to the selected channel for 3 seconds
-
C1
key
for channel
- key
for channel C2 (only for the dual-channel model)
5. Press
appears on the display for a few seconds and the count is reset.
OK
:
OKAY
6. Exit and return to the home screen by pressing the
key three times.
MENU
Attention:
if you change the maintenance interval any partial count already taken will be lost.
Attention
MAINTEN
:
C
when the
text is deleted, the counter is automatically rebooted and the
count starts again.
9.3.a) Managing a maintenance operation
- Once the operating hours set for one or both channels (dual-channel model) are reached,
MAINTEN
will appear on the main screen in cyclic repetition alternating with the current
DATE
(example in the figure at the side: channel 1 in Maintenance).
In this condition you can override the status of the outputs (from the MANUAL menu) and
-
manage the maintenance intervention.
- Eliminate the maintenance alert from the main screen by:
- keeping the
key pressed for 3 seconds to reset the alarm of channel C1,
- keeping the
key pressed for 3 seconds to reset the alarm of channel C2
(
).
dual-channel model
This will reset the channel and the count of the hours set starts from the beginning.