Konstruktion
:
Please
follow
the
below
menu
instructions
to
optimize
VP3
Sector
Scout
‐
based
scheduling.
Sensor
afterrun
time
The
integrated
valve
has
a
closing
time
of
about
5
‐
8
seconds,
so
the
sensor
will
send
a
signal
to
the
controller
about
15
seconds
before
the
sprinkler
has
reached
the
sector
stop.
The
sensor
afterrun
time
can
also
be
used
to
make
sure
that
the
VP3
pops
down
when
it
reaches
the
sector
stop.
It
can
furthermore
individually
be
adjusted
for
the
left
and
right
arc
setting.
Please
note
that
the
times
specified
are
subject
to
changing
values
like
rotation
speed
and
operating
pressure
at
the
sprinkler
and
may
therefore
vary.
Below
is
a
schematic
view
of
Sector
Scout
‐
based
scheduling:
The
following
simplified
version
will
appear
on
the
display:
Press
and
to
select
„Sensor
setup“.
Then
press
to
confirm.